Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF INTERIOR, U.S. GEOLOGICAL SURVEY, WATER SCIENCE CENTER, ESCANABA FIELD OFFICE

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of U.S. DEPARTMENT OF INTERIOR, U.S. GEOLOGICAL SURVEY, WATER SCIENCE CENTER, ESCANABA FIELD OFFICE in 1601 LUDINGTON ST 2ND FLOOR, ESCANABA, MI 49829 (NAICS 924120). OSHA activity number 343058392.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Interior, U.S. Geological Survey, Water Science Center, Escanaba Field Office — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Interior, U.S. Geological Survey, Water Science Center, Escanaba Field Office is published. One employer, no account, unsubscribe in one click.
Site address
1601 LUDINGTON ST 2ND FLOOR
City
ESCANABA
State
MI
ZIP
49829
Mailing
6520 MERCANTILE WAY SUITE 5, LANSING, MI 48911
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
5
Ownership type
D

6 citations on file for this inspection.

1910.146 C01

Serious Gravity 5 7 instances 5 exposed
Issued
Jul 12, 2018
Abate by
Aug 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  On or about March 27, the employer had not made an evaluation to determine if the stilling wells at the gaging stations serviced by the Escanaba Field Office were permit required confined spaces. The stilling wells contained water engulfment hazards and potentially hazardous atmospheres.
Recent events (1)
  • — Z (S) $0

1910.146 C02

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 12, 2018
Abate by
Aug 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:  On or about March 28, 2018, the employer did not ensure danger signs were posted at the Ford River near Hyde gaging station with had a stilling well  where employees could enter through a floor hatch. Entry into the stilling well could expose employees to water engulfment hazards and potentially hazardous atmospheres.   NOTE: A sign reading DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language would satisfy the requirement for a sign.
Recent events (1)
  • — Z (S) $0

1910.146 D03

Serious Gravity 5 7 instances 5 exposed
Issued
Jul 12, 2018
Abate by
Aug 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations:  On or about March 27, 2018, the employer had not developed and implemented procedures for safe permit space entry when employees were required to enter stilling wells to install and remove frost floors. Entry into the stilling well could expose employees to water engulfment hazards and potentially hazardous atmospheres.
Recent events (1)
  • — Z (S) $0

1910.146 D09

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 12, 2018
Abate by
Aug 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(9): The employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and/or for preventing unauthorized entry.  On or about March 27, 2018, the employer did not develop and implement rescue procedures for employees required to enter permit required confined spaces such as stilling wells when installing and removing frost floors.
Recent events (1)
  • — Z (S) $0

1910.146 D10

Serious Gravity 5 7 instances 5 exposed
Issued
Jul 12, 2018
Abate by
Aug 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(10): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement a system for the preparation, issuance, use, and cancellation of entry permits as required:   On or about March 27, 2018, the employer did not develop and implement an entry permit system for use when employees were required to enter permit required confined spaces such as stilling wells when installing and removing frost floors.
Recent events (1)
  • — Z (S) $0

1910.146 G01

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 12, 2018
Abate by
Nov 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:  On or about March 27, 2018, the employer did not provide training on permit entry procedures and rescue procedures to employees required to enter permit required confined spaces such as stilling wells when installing and removing frost floors.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343058392.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.