Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EURO MARBLE SUPPLY, LTD, DBA EURO MARBLE & GRANITE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EURO MARBLE SUPPLY, LTD, DBA EURO MARBLE & GRANITE, INC. in 4552 RUBY ST., SCHILLER PARK, IL 60176 (NAICS 327991). OSHA activity number 343064812.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Euro Marble Supply, LTD, DBA Euro Marble & Granite, INC. — free Get an email when a new federal OSHA severe-injury report for Euro Marble Supply, LTD, DBA Euro Marble & Granite, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4552 RUBY ST.
City
SCHILLER PARK
State
IL
ZIP
60176
Mailing
4552 RUBY ST., SCHILLER PARK, IL 60176
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
30
Ownership type
A

9 citations on file for this inspection.

1910.147 C05 II

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 11, 2018
Abate by
Sep 21, 2018
Penalty
Initial $6,467 · Current $4,093 Reduced
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified:    (a) Production - On April 5, 2018, the employer did not ensure that the BACA robot locked out for servicing and repair, was locked using devices which were singularly identified.     In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $4093
  • — C (S) $6467
  • — Z (S) $6467

1910.147 C06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 11, 2018
Abate by
Sep 21, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:    (a) Facility Wide - On April 5, 2018, the employer failed to ensure that periodic inspections of the energy control procedures were performed and contained the required documentation such as the identification of the machine or equipment, inspection date, employees included and the person performing the inspection.    In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (5)
  • — I $0
  • — Z $13260
  • — F (S) $0

1910.179 G01 V

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 11, 2018
Abate by
Sep 21, 2018
Penalty
Initial $7,760 · Current $1,814 Reduced
29 CFR 1910.179(g)(1)(v): Pendant control boxes were not constructed to prevent electrical shock or clearly marked for identification of functions:    (a) Yard - On April 5, 2018, the employer did not ensure that pendant boxes on the Sessco crane serial #NS18-0410000009 were clearly marked for identification and buttons were maintained with reinforced rubber enclosures. The crane was located outside and exposed to weather elements.      In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $1814
  • — C (S) $7760
  • — Z (S) $7760

1910.179 N04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 11, 2018
Abate by
Sep 28, 2018
Penalty
Initial $7,760 · Current $0 Reduced
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load, at the beginning of each operator's shift:    (a) Yard  - On April 5, 2018, the employer did not ensure that the Sessco Crane Serial # NS18-0410000009 upper hoist limit switch was tried out at the beginning of each operator's shift. The crane is located outside and exposed to weather elements. Various components of the crane were worn, damaged and needed to be replaced.        In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $7760
  • — Z (S) $7760

1910.179 J02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 11, 2018
Abate by
Sep 21, 2018
Penalty
Initial $5,174 · Current $4,093 Reduced
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed:    (a) Yard - On April 5, 2018, the employer did not conduct a monthly inspection of the Sessco crane serial #NS18-0410000009 crane's hooks. The monthly inspection should include a certification record which identifies the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier of the hook being inspected.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $4093
  • — C (S) $5174
  • — Z (S) $5174

1910.179 J02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 11, 2018
Abate by
Sep 21, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed:  (a) Yard - On April 5, 2018,  the employer did not conduct a monthly inspection of the Sessco crane serial #NS18-0410000009 hoist chains. The monthly inspection should include a certification record which identifies the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier of the chain being inspected.  In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.179 L01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 11, 2018
Abate by
Sep 28, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.179(l)(1): A preventive maintenance program based on the crane manufacturer's recommendations was not established:    (a) Facility Wide - On April 5, 2018, the employer did not implement a preventative maintenance program based on the cranes manufacturer's recommendations. The crane is located outside and exposed to weather elements. Various components of the crane were worn, damaged and needed to be replaced.       In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (S) $0
  • — C (S) $9054
  • — Z (S) $9054

1910.132 D02

Other-than-serious 1 instance 15 exposed
Issued
Sep 11, 2018
Abate by
Sep 28, 2018
Penalty
Initial $726 · Current $0 Reduced
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):    (a) Facility Wide - On April 5, 2018, the employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed and the date(s) of the hazard assessment.           In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (O) $0
  • — C (O) $726
  • — Z (O) $726

1910.303 B01

Other-than-serious 1 instance 3 exposed
Issued
Sep 11, 2018
Abate by
Sep 21, 2018
Penalty
Initial $726 · Current $0 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a) Yard - On April 5, 2018, the employer did not ensure that the Sessco crane pendant control was free from recognized hazards. in that the pendant control had a damaged cord.     In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (O) $0
  • — C (O) $726
  • — Z (O) $726

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343064812.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.