On , OSHA opened a referral safety inspection of G G & S CONSTRUCTION in 3801 S HARDIN BLVD, MCKINNEY, TX 75069 (NAICS 238140). OSHA activity number 343070488.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G G & S CONSTRUCTION
- Site address
- 3801 S HARDIN BLVD
- City
- MCKINNEY
- State
- TX
- ZIP
- 75069
- Mailing
- 105 S. TENNESSEE ST. SUITE 102, MCKINNEY, TX 75069
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B07
- Issued
- Jun 15, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $11,641 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(7): On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement. On or about April 3, 2018 employees were exposed to a fall hazard of approximately 20 feet when not overlapping planks on the supports.
Recent events (2)
- — I (S) $0
- — Z (S) $11641
1926.451 C03
- Issued
- Jun 15, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $11,641 · Current $8,500 Reduced
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement. On or about April 3, 2018 Employees were exposed to a fall hazard approximately 20 feet to the lower ground when scaffold frame was not plumb.
Recent events (2)
- — I (O) $8500
- — Z (S) $11641
1926.452 C02
- Issued
- Jun 15, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $11,641 · Current $0 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. On or about April 3, 2018 employees were exposed to a fall of approximately 20 feet in height to the lower ground level when not installing the horizontal braces on Non-Stop scaffold.
Recent events (2)
- — I (O) $0
- — Z (S) $11641