SEVERANCE, CO —
OSHA Inspection: SAMPSON CONSTRUCTION CO., INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of SAMPSON CONSTRUCTION CO., INC. in 1200 HIDDEN VALLEY PARKWAY, SEVERANCE, CO 80550 (NAICS 236220). OSHA activity number 343074357.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMPSON CONSTRUCTION CO., INC.
- Site address
- 1200 HIDDEN VALLEY PARKWAY
- City
- SEVERANCE
- State
- CO
- ZIP
- 80550
- Mailing
- 3730 S 14TH STREET, LINCOLN, NE 68502
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 316
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.20 B02
- Issued
- Sep 28, 2018
- Abate by
- Oct 25, 2018
- Penalty
- Initial $8,315 · Current $8,315
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) designated by the employers in the following instances: a) Sampson Construction Co., Inc. at 1200 Hidden Valley Parkway, Severance, CO 80550: On or before April 4, 2018, the controlling employer did not ensure that competent person inspections were performed on the steel erection of the west staircase in Area E. Erection aid tabs used to connect the west and north horizontal tube steel beams to the columns were not designed, rated, and approved by a qualified engineer. In addition, these erection aid tabs were tack welded to the west columns, and this welding was not inspected by a qualified weld inspector. The employer did not ensure that competent person inspections were performed of the steel erection process of the west staircase of Area E; b) Sampson Construction Co., Inc. at 1200 Hidden Valley Parkway, Severance, CO 80550: On April 4, 2018, the controlling employer allowed a concrete pump truck to set up and boom into Area E through the west side staircase, even though parts of the steel erection for the staircase were not structurally stable. At approximately 10:10 am, a concrete pump truck struck the west upper horizontal tube steel beam with its boom. The beam fell and struck an employee of the concrete delivery company, resulting in fatal injuries. A competent person did not ensure that the location used to set up the concrete pump truck presented a safe place for concrete pumping operations; c) Sampson Construction Co., Inc. at 1200 Hidden Valley Parkway, Severance, CO 80550: At approximately 7:10 am on April 4, 2018, while setting up to pump concrete, a concrete pump truck boom struck the upper horizontal tube steel beam on the west side of the staircase in Area E. The controlling employer did not ensure that a competent person inspected the beam and its supports after this first strike, and before continuing with concrete pumping operations. No adjustments were made to the concrete pump truck setup, and no barricades were set out to prevent employee access in and around the west staircase. At approximately 10:10 am, a concrete pump truck struck the west upper horizontal tube steel beam with its boom a second time. The beam fell and struck an employee of the concrete delivery company, resulting in fatal injuries. These conditions exposed subcontractor employees to the hazard of being struck-by falling steel beams.
Recent events (1)
- — Z (S) $8315
1926.754 A
- Issued
- Sep 28, 2018
- Abate by
- Oct 25, 2018
- Penalty
- Initial $8,315 · Current $8,315
General-duty citation text
29 CFR 1926.754(a): Structural stability was not maintained at all times during the erection process: a) Sampson Construction Co., Inc. at 1200 Hidden Valley Parkway, Severance, CO 80550: On and before April 4, 2018, the controlling employer did not ensure that structural stability was maintained at all times during the erection process, in that two horizontal beams along the west staircase of Area E were not structurally stable. Erection aid tabs used to connect the west and north horizontal tube steel beams to the west columns were not designed, rated, and approved by a qualified engineer. In addition, these erection aid tabs were tack welded to the west columns, and this welding was not inspected by a qualified weld inspector. The employer did not ensure that structural stability was maintained at all times during the steel erection process. This condition exposed subcontractor employees to the hazard of being struck-by falling steel.
Recent events (1)
- — Z (S) $8315
More inspections at Sampson Construction CO., INC.
View Sampson Construction CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343074357.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.