Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PROFESSIONAL FABRICATIONS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PROFESSIONAL FABRICATIONS INC. in 550 WOODROW STREET, DENMARK, WI 54208 (NAICS 332322). OSHA activity number 343079158.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Professional Fabrications INC. — free Get an email when a new federal OSHA severe-injury report for Professional Fabrications INC. is published. One employer, no account, unsubscribe in one click.
Site address
550 WOODROW STREET
City
DENMARK
State
WI
ZIP
54208
Mailing
550 WOODROW STREET, DENMARK, WI 54208
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
54
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 10 instances 10 exposed
Issued
May 16, 2018
Abate by
Jul 30, 2018
Penalty
Initial $6,467 · Current $3,234 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section:     On or about April 11, 2018 the employer had not developed and/or documented machine specific energy control procedures when employees were engaged in servicing and/or maintenance tasks covered by this section.
Recent events (2)
  • — I (S) $3233.5
  • — Z (S) $6467

1910.147 C06 I

Serious Gravity 5 1 instance 10 exposed
Issued
May 16, 2018
Abate by
Jul 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:       On or about April 11, 2018 the employer had not conducted periodic inspections to ensure that the procedures and the requirements of this standard were being followed during servicing and/or maintenance tasks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 10 instances 10 exposed
Issued
May 16, 2018
Abate by
Jul 30, 2018
Penalty
Initial $6,467 · Current $3,234 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:      On or about April 11, 2018 each authorized employee was not provided the training required by this standard and were exposed to potential releases of hazardous energy.
Recent events (2)
  • — I (S) $3233.5
  • — Z (S) $6467

1910.147 C07 I B

Serious Gravity 5 1 instance 42 exposed
Issued
May 16, 2018
Abate by
Jul 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Each affected employee shall be instructed in the purpose and use of the energy control procedure:        On or about April 11, 2018 each affected employee was not provided the work instruction and/or training regarding the purpose and use of energy control procedure(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 8 instances 25 exposed
Issued
May 16, 2018
Abate by
Oct 19, 2018
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle:     a) On or about April 11, 2018 the AFM Fabtek hydraulic brake press point-of-operation was not guarded to prevent employee exposure to the hazardous downward motion of the ram during the bending process.        b) On or about April 11, 2018 the Mitsubishi Toyoxoxi hydraulic brake press point-of-operation was not guarded to prevent employee exposure to the hazardous downward motion of the ram during the bending process.        c) On or about April 11, 2018 the Amada RG-80 hydraulic brake press point-of-operation was not guarded to prevent employee exposure to the hazardous upward motion of the ram during the bending process.        d) On or about April 11, 2018 the Amada RG-50 hydraulic brake press point-of-operation was not guarded to prevent employee exposure to the hazardous upward motion of the ram during the bending process.        e) On or about April 11, 2018 the Amada RG-35S hydraulic brake press point-of-operation was not guarded to prevent employee exposure to the hazardous upward motion of the ram during the bending process.        f) On or about April 11, 2018 the Amada RG-50 hydraulic brake press point-of-operation was not guarded to prevent employee exposure to the hazardous upward motion of the ram during the bending process.        g) On or about April 11, 2018 the Amada Diamond BB 4013 hydraulic brake press point-of-operation was not guarded to prevent employee exposure to the hazardous upward motion of the ram during the bending process.        h) On or about January 11, 2018 the Haeger Pemsert point-of-operation was not guarded to prevent employee exposure to the hazardous force exerted when the upper and lower tool holders made contact and/or a conductive path was created by contact with a conductive surface.
Recent events (2)
  • — I (S) $4527
  • — Z (S) $9054

1910.219 D01

Serious Gravity 5 2 instances 10 exposed
Issued
May 16, 2018
Abate by
May 29, 2018
Penalty
Initial $5,174 · Current $2,587 Reduced
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes:     On or about April 11, 2018 the guards and/or covers were missing from the motor housing exposing the in-running nip points created by the belt and pulleys within the housing.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1910.219 E01 I

Serious Gravity 5 2 instances 10 exposed
Issued
May 16, 2018
Abate by
May 29, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section:  On or about April 11, 2018 the guards and/or covers were missing from the motor housing exposing the in-running nip points created by the belt and pulleys within the housing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343079158.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.