CORTLAND, NY —
OSHA Inspection: JACKSON CONTRACTING, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JACKSON CONTRACTING, LLC. in RIVERSIDE PLAZA, 160 CLINTON AVENUE, CORTLAND, NY 13045 (NAICS 238130). OSHA activity number 343080438.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JACKSON CONTRACTING, LLC.
- Site address
- RIVERSIDE PLAZA, 160 CLINTON AVENUE
- City
- CORTLAND
- State
- NY
- ZIP
- 13045
- Mailing
- 2221 NEWPORT ROAD, POLAND, NY 13431
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.28 A
- Issued
- Jun 20, 2018
- Penalty
- Initial $2,772 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: a) South side of building, front, on or about 4-11-18: One employee was using a circular saw to cut fiber cement siding, without eye protection. b) South side of building, front, on or about 4-11-18: Two employees were using pneumatic nailers to install fiber cement siding, without eye protection.
Recent events (2)
- — I (S) $1200
- — Z (S) $2772
1926.404 B01 II
- Issued
- Jun 20, 2018
- Penalty
- Initial $2,217 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) East wall of interior space, on or about 4-11-18: Employees were operating various power tools, powered through an extension cord that was plugged in to a receptacle that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (2)
- — I (S) $0
- — Z (S) $2217
1926.404 F06
- Issued
- Jun 20, 2018
- Abate by
- Jul 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) East wall of interior space, on or about 4-11-18: Employees were operating various power tools, powered through an extension cord that did not have a continuous path to ground due to improper internal wiring. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G01 III C
- Issued
- Jun 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(1)(iii)(C): Flexible cords and cables were run through doorways, windows, or similar openings: a) South side of building, front, on or about 4-14-18: Employees were powering various power tools through an extension cord that was pinched between two metal doors, subjecting the cord to damage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 C01
- Issued
- Jun 20, 2018
- Abate by
- Jul 2, 2018
- Penalty
- Initial $2,772 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1153(c)(1): The employer did not assess the exposure of each employee who was reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section. a) South side of building, front, on or about 4-14-18: The employer did not assess exposures for employees reasonably expected to be exposed to respirable crystalline silica while cutting James Hardie brand fiber cement siding with a circular saw. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $2772
More inspections at Jackson Contracting, LLC.
View Jackson Contracting, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343080438.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.