OSHA Inspection: IMERYS FUSED MINERALS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of IMERYS FUSED MINERALS, INC. in 3455 HYDE PARK BLVD., NIAGARA FALLS, NY 14305 (NAICS 327910). OSHA activity number 343080552.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Imerys Fused Minerals, INC. — free Get an email when a new federal OSHA severe-injury report for Imerys Fused Minerals, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3455 HYDE PARK BLVD.
City
NIAGARA FALLS
State
NY
ZIP
14305
Mailing
3455 HYDE PARK BLVD., NIAGARA FALLS, NY 14305
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327910
Employees
33
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 8 exposed
Issued
May 14, 2018
Abate by
Jun 27, 2018
Penalty
Initial $6,467 · Current $4,800 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   a) On or about 04/11/2018, Milling Plant North Dust Collector, when employees perform maintenance and servicing activities, such as replacing the screens on the True-Balanced Sifter, energy control procedures were not being utilized, exposing employees to unexpected start of the True-Balanced Sifter.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $4800
  • — Z (S) $6467

1910.147 E03

Other-than-serious 1 instance 12 exposed
Issued
May 14, 2018
Abate by
Jun 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(e)(3): Lockout or tagout devices removal.  Specific procedures and training for removal of locks from energy isolating device(s) by other than the employee who applied the device were not developed, documented and incorporated into the employer's energy control program:  a) On or about 04/11/2018 throughout establishment; where the employer's documented energy control program did not include procedures for removal of lockout device(s) from energy isolating device(s) by someone other than the employee who applied the lockout device. Procedures must include, at a minimum, the means to accomplish the requirements in 1910.146(e)(3)(i) through 1910.147(e)(3)(iii).  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C05 II

Other-than-serious 1 instance 8 exposed
Issued
May 14, 2018
Abate by
Jun 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not used for lockout and tagout purposes only:   a) On or about 04/11/2018, in the Milling Plant North Dust Collector, employees were using Lockout locks to put the True Balance Sifter out of service instead of using out of service locks.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343080552.