Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BCG BROCK CONSTRUCTION GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BCG BROCK CONSTRUCTION GROUP in 126 BELVIDERE ST, NAZARETH, PA 18064 (NAICS 236220). OSHA activity number 343081709.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BCG Brock Construction Group — free Get an email when a new federal OSHA severe-injury report for BCG Brock Construction Group is published. One employer, no account, unsubscribe in one click.
Site address
126 BELVIDERE ST
City
NAZARETH
State
PA
ZIP
18064
Mailing
4130 SKY PINE WAY, EAST STROUDSBURG, PA 18301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
30
Ownership type
A

2 citations on file for this inspection.

1926.403 I02 I

Deleted Serious Gravity 5 2 instances 10 exposed
Issued
Jul 9, 2018
Penalty
Initial $6,467 · Current $0 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.  a) Basement area - On or about April 14, 2018, employees were using receptacles, containing live parts energized to 120 volts AC, to provide power to construction equipment and portable tool, but several of the receptacle plate covers were missing.  b) Basement area - On or about April 14, 2018, employees were using circuit breakers in a panel, containing live parts energized to 240 volts AC without the cover or dead front installed, to control power in the building for construction equipment and lighting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6467

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 9, 2018
Penalty
Initial $5,174 · Current $4,800 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a) Basement area - On or about April 14, 2018, employees were performing work along an unprotected edge, approximately 7 feet above the lower level basement, without utilizing guardrail systems, safety net systems, or personal fall arrest systems.
Recent events (2)
  • — I (S) $4800
  • — Z (S) $5174

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343081709.