BOSSIER CITY, LA —
OSHA Inspection: LATHAM POOL PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LATHAM POOL PRODUCTS, INC. in 5000 HAZEL JONES ROAD, BOSSIER CITY, LA 71111 (NAICS 326199). OSHA activity number 343082269.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LATHAM POOL PRODUCTS, INC.
- Site address
- 5000 HAZEL JONES ROAD
- City
- BOSSIER CITY
- State
- LA
- ZIP
- 71111
- Mailing
- 5000 HAZEL JONES ROAD, BOSSIER CITY, LA 71111
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 57
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 II
- Issued
- Jun 5, 2018
- Abate by
- Jun 15, 2018
- Penalty
- Initial $6,467 · Current $3,880 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)[A], 29 CFR 1910.147(c)(4)(ii)[B], 29 CFR 1910.147(c)(4)(ii)[C], and 29 CFR 1910.147(c)(4)(ii)[D]: On or about 04/11/2018, the employer did not ensure that written lock-out/tag-out procedures were machine specific for an Eastman Eagle single ply conveyor cutter and an Eastman EC3 (M9000) textile conveyor cutting machine, which utilize both electric and pneumatic energy. Procedures did not include specific steps for each machine for a) shutting down, isolating, blocking, and securing the machine to control hazardous energy; b) placing, removing, and transferring of locks/tags; and c) testing the machine to verify that lock-out/tag-out was effective.
Recent events (2)
- — I (S) $3880.2
- — Z (S) $6467
More inspections at Latham Pool Products, INC.
View Latham Pool Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343082269.