Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NFM WELDING ENGINEERS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NFM WELDING ENGINEERS INC. in 577 OBERLIN ROAD, MASSILLON, OH 44646 (NAICS 332710). OSHA activity number 343083770.

Watch NFM Welding Engineers INC. — free Get an email when a new federal OSHA severe-injury report for NFM Welding Engineers INC. is published. One employer, no account, unsubscribe in one click.
Site address
577 OBERLIN ROAD
City
MASSILLON
State
OH
ZIP
44646
Mailing
577 OBERLIN ROAD, MASSILLON, OH 44646
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
145
Ownership type
A

8 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $4989.00 · Current $2993.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition:    On or about April 12, 2018, the saw department had a variety of steel bar stock on the floor, on stands and on racks. Employees had to step on, walk on and stand on the steel bars while using the overhead crane to retrieve stock for the saw. There were no walking working aisles established.
Recent events (2)
  • — I (S) $2993.4
  • — Z (S) $4989

1910.179 J02

Serious Gravity 5 4 instances 10 exposed
Issued
Abate by
Penalty
Initial $8315.00 · Current $4989.00 Reduced
29 CFR 1910.179(j)(2): Frequent inspections of the cranes were not performed at intervals as generally defined in paragraph (j)(1)(ii)(a) of this section or as specifically indicated:    On or about April 12, 2018, a frequent inspection of the cranes was not performed. The overhead cranes such as but not limited to the 5 ton Wright overhead crane in the saw department was missing bridge bumpers. The Electrolift hoist at the CNC machine had a pendant controller with the electrical wiring insulation damaged. The 10 ton Cleveland overhead crane in the production area was not marked with the load capacity and the Shaw box crane in the center of the production building that was between two cranes on the same rail system had a broken gear box that would not allow the crane to travel the rails on its own power.
Recent events (2)
  • — I (S) $4989
  • — Z (S) $8315

1910.179 J03

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:     On or about April 12, 2018, a complete periodic inspection of the cranes was not performed. Employees use the overhead cranes throughout the departments to move large steel stock and large parts from storage to machinery. The employer was using a monthly cable, drum and hook inspection sheet as their annual inspection of their cranes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $8315.00 · Current $4989.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about April 12, 2018, the Johnford CNC ST-60CH lathe in the production area had a non-working interlock at the top of the machine door opening. While the machine is running with the door open and rotating the part, an employee uses a hand file to remove any burrs on the edge of the rotating part.
Recent events (2)
  • — I (S) $4989
  • — Z (S) $8315

1910.215 B09

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $4989.00 · Current $2993.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:     On or about April 12, 2017, the GE abrasive wheel pedestal grinder in the CNC building of the production area was missing the periphery guard and had an opening of 5/8 of an inch.
Recent events (2)
  • — I (S) $2993.4
  • — Z (S) $4989

1910.242 B

Serious Gravity 1 3 instances 6 exposed
Issued
Penalty
Initial $4989.00 · Current $2993.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:     On or about April 13, 2018, at both CNC lathes in small production building and the large lathe at the northwest wall of the main production area employees were using compressed air for cleaning that was at 90 psi.
Recent events (2)
  • — I (S) $2993.4
  • — Z (S) $4989

1910.303 G02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $8315.00 · Current $4989.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about April 12, 2017, employees were exposed to live electric parts at the northwest wall in the CNC production area. There was a 110/220 volt electrical distribution panel with an open cover. Two of the over current devices were missing from the panel and were not blanked.
Recent events (2)
  • — I (S) $4989
  • — Z (S) $8315

1910.305 B01 I

Other-than-serious 2 instances 10 exposed
Issued
Penalty
Initial $4989.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:     On or about April 12, 2017, there were two industrial pedestal fans with control switch wiring that was subject to abrasion. The electrical junction boxes were damaged and not securely attached to the back side of the fan housings. One of the fans were in the CNC room and the other fan was in the production area.