WOODLAND PARK, CO —
OSHA Inspection: EDMOND PLAZA CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EDMOND PLAZA CONSTRUCTION, LLC in 721 US HIGHWAY 24, WOODLAND PARK, CO 80863 (NAICS 236220). OSHA activity number 343087789.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDMOND PLAZA CONSTRUCTION, LLC
- Site address
- 721 US HIGHWAY 24
- City
- WOODLAND PARK
- State
- CO
- ZIP
- 80863
- Mailing
- 6504 SW 29TH ST, OKLAHOMA CITY, OK 73179
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 18
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B01
- Issued
- May 16, 2018
- Abate by
- May 22, 2018
- Penalty
- Initial $4,434 · Current $4,434
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system: (a) On or about April 10, 2018, and at times prior, employees were exposed to fall hazards of nine feet and greater in that they worked from the third level deck adjacent to the leading edge without fall protection in place. (b) On or about April 10, 2018, and at times prior, employees were exposed to fall hazards in excess of six feet in that the open sided floor above the stairwell located on the west side of the building did not have a guardrail system in place. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $4434
1926.501 B14
- Issued
- May 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet or more above lower levels and the inside bottom edge of the wall opening: (a) On or about April 10, 2018, and at times prior, employees were exposed to fall hazards of approximately twelve feet to ground level where a four foot section of the outside west wall was unprotected. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1926.502 B01
- Issued
- May 16, 2018
- Abate by
- May 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: (a) On or about April 10, 2018, and at times prior, employees were exposed to fall hazards at 24 wall openings, where the highest protective barrier was located approximately 34 inches above the walking working surface. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1926.502 B03
- Issued
- May 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: (a) On or about April 10, 2018, and at times prior, workers were exposed to fall hazards at the second level elevator access where the guard rail system was not constructed to withstand a force of 200 pounds in the outward direction. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1926.1052 C01 I
- Issued
- May 16, 2018
- Abate by
- May 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: (a) On or about April 10, 2018, and at times prior, workers were exposed to slip and trip hazards where the stair systems on the east and west of end the building were not equipped with at least one handrail. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (O) $0
More inspections at Edmond Plaza Construction, LLC
View Edmond Plaza Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343087789.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.