Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R.C.O. PLUMBING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of R.C.O. PLUMBING, INC. in 2104 N. CHESTNUT AVE., ARLINGTON HEIGHTS, IL 60004 (NAICS 237110). OSHA activity number 343088860.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.C.O. Plumbing, INC. — free Get an email when a new federal OSHA severe-injury report for R.C.O. Plumbing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2104 N. CHESTNUT AVE.
City
ARLINGTON HEIGHTS
State
IL
ZIP
60004
Mailing
2613 MARWOOD ST., RIVER GROVE, IL 60171
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2018
Penalty
Initial $3,880 · Current $1,000 Reduced
29 CFR 1926.100(a):  Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:        a) On or about April 12, 2018, employees working in a trench were not wearing protective helmets where there was a possible danger of head injury from falling objects.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3880

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2018
Abate by
Oct 10, 2018
Penalty
Initial $3,880 · Current $1,940 Reduced
29 CFR 1926.651(c)(2):  A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees:      a)  On or about April 12, 2018, employees were not provided with a safe means of egress when working in a trench approximately 18 feet deep.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2018
Abate by
Oct 10, 2018
Penalty
Initial $3,880 · Current $1,940 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:       a) On or about April 12, 2018, an extension ladder used by employees to access and egress the trench did not have its side rails extended at least 3 feet above the ground.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1926.651 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2018
Abate by
Oct 10, 2018
Penalty
Initial $3,880 · Current $1,000 Reduced
29 CFR 1926.651(j)(2):  Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:      a) On or about April 12, 2018, employees were not protected from the hazard of falling or rolling excavated material that was placed and kept at the edge of the trench.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3880

1926.1000 B

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2018
Abate by
Oct 10, 2018
Penalty
Initial $3,880 · Current $1,000 Reduced
29 CFR 1926.1000(b): Material handling equipment manufactured on or after September 1, 1972, was not equipped with rollover protective structure(s):    a) On or about April 12, 2018, employees used Bobcat - E32 Compact Excavator without rollover protection during sewer service installation work.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3880

1926.652 A01

Willful Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2018
Abate by
Oct 10, 2018
Penalty
Initial $25,867 · Current $18,120 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c):        a)  On or about April 12, 2018, employees were not protected from the hazard of cave-in while working in a trench measuring approximately 18 feet in depth.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (W) $18120
  • — Z (W) $25867

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343088860.