CHAPMANVILLE, WV —
OSHA Inspection: PAR ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PAR ROOFING, INC. in 97 TIGER CIRCLE, CHAPMANVILLE, WV 25508 (NAICS 238160). OSHA activity number 343096392.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PAR ROOFING, INC.
- Site address
- 97 TIGER CIRCLE
- City
- CHAPMANVILLE
- State
- WV
- ZIP
- 25508
- Mailing
- 543 WASHINGTON AVENUE, HUNTINGTON, WV 25701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 26
- Ownership type
- A
Citations
11 citations on file for this inspection.
1926.102 A01
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $3,880 · Current $2,406 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: (a) Kitchen roof: On or about April 11, 2018, and times prior, an employee was not wearing eye protection when using a 7 1/4in. Porter Cable circular saw to cut pieces of plywood for a parapet wall on the roof.
Recent events (2)
- — I (S) $2406
- — Z (S) $3880
1926.404 F06
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $5,174 · Current $3,208 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) Kitchen roof: On or about April 11, 2018, and times prior, a Porter Cable circular saw was used by an employee to cut wood pieces for the top of the parapet wall. The circular saw was powered by a 12AWG extension cord that was missing a ground pin.
Recent events (2)
- — I (S) $3208
- — Z (S) $5174
1926.501 B04 I
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $6,467 · Current $4,035 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. (a) Administrative offices roof: On or about April 11, 2018, and times prior, employees climbed through a roof hatch measuring 32 5/8in. by 56in. and were exposed to falls of 17ft. 1in. due to not covering the roof hatch opening while on the roof performing roofing work.
Recent events (2)
- — I (S) $4035
- — Z (S) $6467
1926.502 D02
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $6,467 · Current $4,035 Reduced
General-duty citation text
29 CFR 1926.502(d)(2): Connectors did not have a corrosion-resistant finish and all surfaces and edges were not smooth to prevent damage to interfacing parts of the system. (a) Kitchen roof: On or about April 11, 2018, and times prior, as part of a fall protection system, while working at heights of up to 18 foot, an employee used a 50ft. vertical lifeline and rope grab connected to a 3ft. rope positioning lanyard with snaphooks at each end that was visibly rusted and corroded.
Recent events (2)
- — I (S) $4035
- — Z (S) $6467
1926.502 D21
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service. (a) Kitchen roof: On or about April 11, 2018, and times prior, the personal fall arrest systems provided by the company and used by employees was not required to be inspected prior to use and defective components, such as rusted/corroded metal components and a harness missing the identification labels was worn while performing roofing work and was not removed from service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D15
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: (a) Kitchen Roof: On or about April 11, 2018, and times prior, employees applying adhesive to the roof parapet were exposed to falls of approximately 18 feet while lanyards attached to their body harnesses were held by coworkers.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.32 A04
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $1,294 · Current $816 Reduced
General-duty citation text
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30. (a) Chapmanville Intermediate School building: On or about April 11, 2018, and times prior, the employer did not post or make available the OSHA 300A, Summary of work-related injuries and Illnesses at the jobsite or at the company office located in Huntington, WV.
Recent events (2)
- — I (O) $816
- — Z (O) $1294
1926.50 D01
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.50(d)(1): First-aid supplies were not easily accessible when required. (a) Chapmanville Intermediate School building: On or about April 11, 2018, and times prior, first aid supplies were not available at the construction jobsite for employees performing work on the site.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1053 B16
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and withdrawn from service until repaired: (a) Chapmanville Intermediate School building: On or about April 11, 2018, and times prior, a 24ft. Werner extension ladder with two bent rungs was used to gain access to the administrative offices.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G08
- Issued
- Jul 26, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s), as referenced by Construction Standard 1926.59: (a) Chapmanville Intermediate School building roof: On or about April 11, 2018, and times prior, the employer did not maintain copies of the required safety data sheets at the jobsite for employees using Firestone EPDM bonding adhesive, Firestone quick primer, insulation adhesive, and seam wash that are flammable and contain chemicals such as, acetone, toluene, and other solvents.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Jul 26, 2018
- Abate by
- Aug 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area, as referenced by Construction Standard 1926.59. (a) Chapmanville Intermediate School building roof: On or about April 12, 2018, and times prior, employees were using hazardous substances during the installation of the EPDM roofing system and the employer did not provide training on the hazards of acetone, toluene, and other solvents.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PAR Roofing, INC.