OSHA Inspection: CW PRECISION FABRICATION AND WELDING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CW PRECISION FABRICATION AND WELDING, INC. in 13118 SUNDALE RD., HOUSTON, TX 77038 (NAICS 332322). OSHA activity number 343098026.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CW Precision Fabrication and Welding, INC. — free Get an email when a new federal OSHA severe-injury report for CW Precision Fabrication and Welding, INC. is published. One employer, no account, unsubscribe in one click.
Site address
13118 SUNDALE RD.
City
HOUSTON
State
TX
ZIP
77038
Mailing
13118 SUNDALE RD., HOUSTON, TX 77038
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
13
Ownership type
A

11 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 10 exposed
Issued
Jun 7, 2018
Abate by
Aug 17, 2018
Penalty
Initial $5,174 · Current $2,587 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On or about April 19, 2018, and times prior thereto, at the facility where employees were exposed to caught-in, struck-by, and electrical hazards while performing maintenance and servicing work on punch press machines without having an energy control program that included energy control procedures, employee training and periodic inspections.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1910.212 A01

Serious Gravity 10 6 instances 5 exposed
Issued
Jun 7, 2018
Abate by
Nov 17, 2018
Penalty
Initial $5,174 · Current $2,587 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about April 19, 2018, and times prior thereto:    a.  In the Cleaning Room in Fabrication Shop, where employees were exposed to caught in hazard, while using a Belt Sander, Make and Model unknown without a guard on the nip points of the sanding belt.    b.  In the Cleaning Room in Fabrication Shop, where employees were exposed to caught in hazard, while using a Baldor Belt Sander, Model GL 3503 without a guard on the nip points of the sanding belt.    c.  In the Cleaning Room in Fabrication Shop, where employees were exposed to caught in hazard, while using a Dayton Belt Sander, Model unknown without a guard on the nip points of the sanding belt.    d.  In the Welding Shop, where employees were exposed to struck-by and caught-by hazards when operating a Lexas, LX-460NC automatic band saw without the unused portion of the blade being guarded.    e.  In the Welding Shop, where employees were exposed to struck-by and caught-by hazards when operating a Ellis Mitre, Model 3000 band saw without the unused portion of the blade being guarded.    f.  In the Fabrication Shop, where employees were exposed to struck-by and caught-by hazards when operating a Yawei -Nisshinbo HPI-3048 CNC Turret Punch Press with the interlocks by-passed.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1910.212 A03 II

Serious Gravity 5 14 instances 10 exposed
Issued
Jun 7, 2018
Abate by
Nov 17, 2018
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    This violation occurred on or about April 19, 2018, and times prior thereto:      a.  In the Fabrication Shop, where employees were exposed to struck-by and caught-by hazards when operating a E-Mill Acer milling machine, without a point of operation guard.    b.  In the Fabrication Shop, where employees were exposed to struck-by and caught-by hazards when operating a Birmingham milling machine, without a point of operation guard.    c.   In the Cleaning Room in Fabrication Shop, where employees were exposed to struck-by and caught-by hazards when operating a 20" Jet floor drill press, without a point of operation guard.      d.  In the Cleaning Room in Fabrication Shop, where employees were exposed to struck-by and caught-by hazards when operating a 16 1/2" Delta floor drill press, without a point of operation guard.      e.  In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating a Standard Industrial Corp. AB325-12 press brake, without a point of operation guard.    f.  In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating a Wysong 55-6 press brake, without a point of operation guard.    g. In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating a Premier 425.2 press brake, without a point of operation guard.    h.  In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating a Acro 38-6 press brake, without a point of operation guard.    i.  In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating a Strippit Custom 18"/30 press, without a point of operation guard.    j.  In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating a Strippit Custom Super 30-40HD press, without a point of operation guard.    k.  In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating a Wysong Model 1072 shear, without a point of operation guard.    l.  In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating a Wysong Model 1225 shear, without a point of operation guard.    m.  In the Fabrication Shop, where employees were exposed to struck-by and caught-in hazards when operating Adira A. Dias Ramos shear, without a point of operation guard.    n.  In the Welding Shop, where employees were exposed to struck-by and caught-in hazards when operating a Wysong Model 650 shear, without a point of operation guard.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 7, 2018
Abate by
Jun 26, 2018
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:    On or about April 19, 2018, and times prior thereto, in the Cleaning Room in the Fabrication Shop, where employee was exposed to a struck-by hazard when operating a 8" Buffalo Machine Tools, Model B-8CB bench grinder without a work rest installed.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1910.215 B03

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 7, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(3): Bench and/or floor stand grinding machinery had angular exposure of the grinding wheel periphery and sides for safety guard(s) which exceeded 125 degrees where the work required contact with the wheel below the horizontal plane of the wheel spindle:  On or about April 19, 2018, and times prior thereto, in the Cleaning Room in Fabrication Shop, where employee was exposed to a struck-by hazard when operating a 8" Buffalo Machine Tools, Model B-8CB bench grinder without a side guard installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 7, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:  On or about April 19, 2018, and times prior thereto, in the Cleaning Room in Fabrication Shop, where employee was exposed to a struck-by hazard when operating a 8" Buffalo Machine Tools, Model B-8CB bench grinder without a tongue guard installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A01

Other-than-serious 1 instance 10 exposed
Issued
Jun 7, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition.  On or about April 19, 2018, and times prior thereto, in the Fabrication Shop near the Birmingham milling machine employees were exposed to slip and fall hazards when the work area and floors were not kept clean or in sanitary conditions.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L04 III

Other-than-serious 1 instance 4 exposed
Issued
Jun 7, 2018
Abate by
Aug 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    On or about April 19, 2018, and times prior thereto, at the facility, where employees were required to operate forklifts to move material without being evaluated at least every three years, to ensure they could do so safely.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 2 instances 10 exposed
Issued
Jun 7, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a.  On or about April 19, 2018, and times prior thereto, near the North wall in the Welding Shop, where employees were allowed to use a job-made extension cord with an attached plastic junction box that was not installed as listed and labeled.  b.  On or about April 19, 2018, and times prior thereto, near the North wall in the Welding Shop, where employees were allowed to use a job-made extension cord with an attached metal junction box that was not installed as listed and labeled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 2 instances 10 exposed
Issued
Jun 7, 2018
Abate by
Jun 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  On or about April 19, 2018, and times prior thereto:  a.  In the Fabrication Shop on the West wall, where employees  were exposed to electrical hazard when trying to access the electrical panels that were blocked by stored equipment and material.    b. In the Welding Shop on the North wall, where employees were exposed to electrical hazard when trying to access the electrical panels that were blocked by stored equipment and material.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 10 exposed
Issued
Jun 7, 2018
Abate by
Aug 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On or about April 19, 2018, and times prior thereto, in the shop area where employees were required to handle hazardous chemicals before a written hazard communication program had been developed and implemented.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343098026.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.