SENECA FALLS, NY —
OSHA Inspection: CARATOZZOLO ELECTRIC, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CARATOZZOLO ELECTRIC, LLC in 14 EAST BAIRD STREET, SENECA FALLS, NY 13148 (NAICS 238210). OSHA activity number 343100939.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARATOZZOLO ELECTRIC, LLC
- Site address
- 14 EAST BAIRD STREET
- City
- SENECA FALLS
- State
- NY
- ZIP
- 13148
- Mailing
- 32 OAK STREET, SENECA FALLS, NY 13148
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.34 A
- Issued
- Apr 27, 2018
- Abate by
- May 3, 2018
- Penalty
- Initial $5,174 · Current $0 Reduced
General-duty citation text
29 CFR 1926.34(a): Building or structure exits were not so arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it was occupied: a) At the jobsite, in the basement, on or about 3/29/18: There was no available means of egress from the street side unit without passing between studded walls. b) At the jobsite, on the main floor, on or about 3/29/18: The means of egress from the street side of the building would require jumping down from the platform (greater than 8 feet to grade) where there are no stairs and no ladder.
Recent events (2)
- — I (O) $0
- — Z (S) $5174
1926.403 B01
- Issued
- Apr 27, 2018
- Abate by
- May 3, 2018
- Penalty
- Initial $5,174 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: a) At the jobsite, in the basement, on or about 3/29/18: Workers were exposed to electrical hazards where an outlet box was used to hard-wire a space heater and the live wires were exposed to incidental contact.
Recent events (2)
- — I (O) $0
- — Z (S) $5174
1926.501 B01
- Issued
- Apr 27, 2018
- Abate by
- May 3, 2018
- Penalty
- Initial $5,174 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) At the jobsite, on the main level, on or about 3/29/18: The primary means of accessing the worksite passed over a platform 8 feet from grade with no fall protection of any kind.
Recent events (2)
- — I (O) $0
- — Z (S) $5174
1926.403 B01 I
- Issued
- Apr 27, 2018
- Abate by
- May 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) At the jobsite, in the basement, on or about 3/29/18: Workers were exposed to electrical hazards when a metal quad box was used to source electricity to a heater, where that box was not attached to a solid surface as it is designed to be. b) At the jobsite, in the basement, on or about 3/29/18: Workers were exposed to electrical hazards when a heater plug was removed and hard wired into the electrical power source.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.404 B01 I
- Issued
- Apr 27, 2018
- Abate by
- May 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, in the basement, on or about 3/29/18: Workers were using power tools, energized without GFCI protection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1052 C01 II
- Issued
- Apr 27, 2018
- Abate by
- May 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) At the jobsite, on the main level, on or about 3/29/18: The stairway accessing the primary means of accessing the building did not have a handrail along each unprotected side.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1052 C04
- Issued
- Apr 27, 2018
- Abate by
- May 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: [ok](a)(LOCATION)(IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS) a) At the jobsite, on the main level, on or about 3/29/18: The stairway accessing the primary means of entrance to the building did not have a mid-rail.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Caratozzolo Electric, LLC
View Caratozzolo Electric, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343100939.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.