CHINLE, AZ —
OSHA Inspection: 3D
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 3D in CHINLE ELDERLY CARE RENOVATION, #170298, CHINLE, AZ 86503 (NAICS 238140). OSHA activity number 343102158.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3D
- Site address
- CHINLE ELDERLY CARE RENOVATION, #170298
- City
- CHINLE
- State
- AZ
- ZIP
- 86503
- Mailing
- P.O. BOX 578, DURANGO, CO 81302
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 B01
- Issued
- May 22, 2018
- Penalty
- Initial $3,298 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch wide except where the employer can demonstrate that a wider space is necessary: Chinle Elderly Care Renovation, #170298: The employer did not ensure that a supported scaffold used for stucco application was fully planked between the platform and the uprights creating a slip, trip, or fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $3298
1926.451 C02
- Issued
- May 22, 2018
- Penalty
- Initial $3,298 · Current $500 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: Chinle Elderly Care Renovation, #170298: The employer did not ensure that a base plate of a supported scaffold used for stucco application was completely supported by the mud sill which can cause it to shift and move. Additionally, a piece of scrap particle board was used as the mud sill.
Recent events (2)
- — I (O) $500
- — Z (S) $3298