Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WOODWARD DESIGN + BUILD, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of WOODWARD DESIGN + BUILD, LLC in 10057 HIGHWAY 190, COVINGTON, LA 70433 (NAICS 337212). OSHA activity number 343104089.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Woodward Design + Build, LLC — free Get an email when a new federal OSHA severe-injury report for Woodward Design + Build, LLC is published. One employer, no account, unsubscribe in one click.
Site address
10057 HIGHWAY 190
City
COVINGTON
State
LA
ZIP
70433
Mailing
1000 S. JEFFERSON DAVIS HWY, NEW ORLEANS, LA 70125
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.95 C01

Other-than-serious 2 instances 2 exposed
Issued
Aug 7, 2018
Abate by
Sep 24, 2018
Penalty
Initial $11,641 · Current $9,313 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent.    On or about April 23, 2018, the employer did not institute an effective hearing conservation program for employees exposed to an 8-hour time-weighted average (TWA) of 85 dBA or greater.  Employee(s), working in and near a paint booth with a ventilation system, was exposed to an 8-hour TWA sound level of 86.6 dBA.
Recent events (3)
  • — R (O) $9312.8
  • — C (S) $11641
  • — Z (S) $11641

1910.107 B09

Other-than-serious 1 instance 2 exposed
Issued
Aug 7, 2018
Abate by
Aug 24, 2018
Penalty
Initial $4,989 · Current $3,991 Reduced
29 CFR 1910.107(b)(9): Spray booths were not so installed that all portions were readily accessible for cleaning. A clear space of not less than 3 feet on all sides were not kept free from storage or combustible construction.    On or about April 24, 2018 at the spray booth side of the shop, the employer did not ensure  that a clear space on all sides of the spray booth existed. In addition these obstructions consisted of flammable material.
Recent events (3)
  • — R (O) $3991.2
  • — C (S) $4989
  • — Z (S) $4989

1910.107 E02

Other-than-serious 1 instance 2 exposed
Issued
Aug 7, 2018
Penalty
Initial $7,068 · Current $5,654 Reduced
29 CFR 1910.107(e)(2): The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 degrees F (93 degrees C) kept in the vicinity of spraying operations were not a minimum required for operations or they exceeded a supply for one day or one shift:    On or about April 23, 2018, at the larger paint booth, the employer allowed an amount of paints and thinners  to be stored in the paint booth to exceed a shift or one days supply.
Recent events (3)
  • — R (O) $5654.4
  • — C (S) $7068
  • — Z (S) $7068

1910.134 H02 I

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Aug 7, 2018
Abate by
Aug 24, 2018
Penalty
Initial $4,989 · Current $0 Reduced
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals:  On or about April 23, 2018, the employer allowed employees to store their respiratory protection in places that did not prevent potential damage to the respirator. The respirators were stored on a shelving unit with various chemicals such as thinners and lacquers. Chemical residues and dust were on the surfaces of the shelves the respirators were stored.
Recent events (3)
  • — F (S) $0
  • — C (S) $4989
  • — Z (S) $4989

View Woodward Design + Build, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343104089.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.