WASHINGTON, DC —
OSHA Inspection: MK KITCHEN AND BATH LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MK KITCHEN AND BATH LLC in 1714 A STREET SE, WASHINGTON, DC 20003 (NAICS 236118). OSHA activity number 343104444.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MK KITCHEN AND BATH LLC
- Site address
- 1714 A STREET SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20003
- Mailing
- 1200 POTOMAC AVE SE, WASHINGTON, DC 20003
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 8
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.102 A01
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $3,880 · Current $1,425 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) On or about April 20, 2018; roof area; employees were exposed to a struck by hazard while operating a Dewalt pneumatic nail gun without wearing eye protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $1425
- — C (S) $3880
- — Z (S) $3880
1926.403 B02
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $3,880 · Current $1,425 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about April 20, 2018; second floor; employee was using a surge/power strips to provide power to equipment such as but not limited to circular saws and air compressors. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $1425
- — C (S) $3880
- — Z (S) $3880
1926.404 B01 II
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $2,772 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) On or about April 20, 2018; roof area; employees were operating portable equipment such as but not limited to Makita 5007F circular saws that were not protected by a ground-fault circuit interrupter exposing them to a shock hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (S) $1200
- — C (S) $2772
- — Z (S) $2772
1926.405 B02
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $3,880 · Current $1,425 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) On or about April 20, 2018; Throughout site; employees plugged portable equipment into electrical outlet boxes that were missing faceplates. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $1425
- — C (S) $3880
- — Z (S) $3880
1926.501 B13
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $3,880 · Current $1,425 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about April 20, 2018; roof area; employees were walking the top-plate without fall protection in place to protect them from falling 45-feet to ground level. b) On or about April 20, 2018; roof area; employees were working near floor openings such as but not limited to the stair opening that was not guarded exposing them to a 10-foot fall to the lower level. c) On or about April 20, 2018; roof area; employees were working near unguarded wall openings exposing them to a 35-foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $1425
- — C (S) $3880
- — Z (S) $3880
1926.1053 B01
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $5,543 · Current $2,800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) On or about April 20, 2018; roof area; employees were using a 6-foot step ladder to access the top of a 10-foot platform; placing the top of the ladder 4 feet below the platform. The Dila Development and Construction was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 1080479, citation number 1, item number 3a and was affirmed as a final order on 10/29/2015, with respect to a workplace located at 1305 H Street NE Washington DC 20002. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $2800
- — C (S) $5543
- — Z (S) $5543
1926.1053 B13
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $5,543 · Current $2,800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about April 20, 2018; roof area; employees were using the top step of a 6-foot step ladder to access the top of a 10-foot platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $2800
- — C (S) $5543
- — Z (S) $5543
1926.503 B01
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training or when employer relied on training conducted by another employer, the certification record needs to indicate the date the employer determined the prior training was adequate rather than the date of actual training, and the signature of the person who conducted the training or the signature of the employer. a) On or about April 20, 2018; roof area; the employer did not have fall protection training certification. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1926.1053 B15
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use a) On or about April 20, 2018; roof area; no competent person on site to prevent employees from using a 6-foot step ladder which had one of the rear cross-braces damaged/bent. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1926.1053 B16
- Issued
- Oct 18, 2018
- Abate by
- Oct 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired a) On or about April 20, 2018; roof area; employees were using a 6-foot step ladder which had one of the rear cross-braces damaged/bent. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236118)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343104444.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.