ATLANTA, GA —
OSHA Inspection: FLOORING DESIGN GROUP INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of FLOORING DESIGN GROUP INC in 3230 OAKCLIFF INDUSTRIAL STREET, ATLANTA, GA 30340 (NAICS 442210). OSHA activity number 343110565.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLOORING DESIGN GROUP INC
- Site address
- 3230 OAKCLIFF INDUSTRIAL STREET
- City
- ATLANTA
- State
- GA
- ZIP
- 30340
- Mailing
- 3230 OAKCLIFF INDUSTRIAL STREET, ATLANTA, GA 30340
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 442210
- Employees
- 23
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 C01
- Issued
- Jun 5, 2018
- Penalty
- Initial $3,141 · Current $1,885 Reduced
9000
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Flooring Design Group, Inc., 3230 Oakcilff Industrial St., Doraville, GA- At the warehouse, employees were provided and required to use N95 disposable respirators from protection against dust while cutting tiles. A written respiratory protection program was not established or implemented, on or about 4/26/18.
Recent events (2)
- — I (S) $1884.6
- — Z (S) $3141
1910.134 E01
- Issued
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. Flooring Design Group, Inc., 3230 Oakcilff Industrial St., Doraville, GA- At the warehouse, employees were provided and required to use N95 disposable respirators from protection against dust while cutting tiles. Medical evaluations were not performed to determine the employees' ability to use a respirator, on or about 4/26/18.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): Flooring Design Group, Inc., 3230 Oakcilff Industrial St., Doraville, GA- At the warehouse, employees were provided and required to use N95 disposable respirators from protection against dust while cutting tiles. Fit testing was not conducted to ensure the proper fitting of the respirators, on or about 4/26/18.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K01
- Issued
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective training to ensure that each employee could demonstrate knowledge of 1910.134(k)(1)(i) - (vii): Flooring Design Group, Inc., 3230 Oakcilff Industrial St., Doraville, GA- At the warehouse, employees were provided and required to use N95 disposable respirators from protection against dust while cutting tiles. Effective respirator training in accordance with the standard was not provided, on or about 4/26/18.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Jun 5, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Flooring Design Group, Inc., 3230 Oakcilff Industrial St., Doraville, GA- An extension cord was being used to energize heating/drying equipment performed at the same location daily, on or about 4/26/18.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.1200 E01
- Issued
- Jun 5, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $3,696 · Current $2,218 Reduced
9000
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Flooring Design Group, Inc., 3230 Oakcilff Industrial St., Doraville, GA- On or about 04/25/2018 employees cut tiles which contain crystalline silica and painted with a topcoat aerosol classified as flammable. The written hazard communication program was not tailored to the way the program was to be implemented at the site.
Recent events (2)
- — I (S) $2217.6
- — Z (S) $3696
1910.1200 H01
- Issued
- Jun 5, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard that the employees had not previously been trained about was introduced into their work area. Information and training was not designed to cover all applicable categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals: Flooring Design Group, Inc., 3230 Oakcilff Industrial St., Doraville, GA- On or about 04/25/2018 employees cut tiles which contain crystalline silica and painted with a topcoat aerosol classified as flammable. Information and training on the physical and health hazards of the chemicals handled have not been conducted.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 442210)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343110565.