Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: C R MAGNETICS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C R MAGNETICS, INC. in 3500 SCARLET OAK BLVD., SAINT LOUIS, MO 63122 (NAICS 334515). OSHA activity number 343110839.

Watch C R Magnetics, INC. — free Get an email when a new federal OSHA severe-injury report for C R Magnetics, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
C R MAGNETICS, INC.
Site address
3500 SCARLET OAK BLVD.
City
SAINT LOUIS
State
MO
ZIP
63122
Mailing
3500 SCARLET OAK BLVD., SAINT LOUIS, MO 63122
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334515
Employees
28
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6467.00 · Current $3900.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     On 04/25/2018 or about, C R Magnetics, located at 3500 Scarlet Oak Blvd., St. Louis, MO, had not developed, documented and utilized proper procedures for the control of potentially hazardous energy for the Epilog Laser (Model: 8000 Laser System, S/N: 8050-14150522412R) for maintenance and servicing work.
Recent events (2)
  • — I (S) $3900
  • — Z (S) $6467

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $3000.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     On 04/25/2018 or about, employee(s) of C R Magnetics, located at 3500 Scarlet Oak Blvd., St. Louis, MO, were exposed to hazards such as those created by the rotating chuck and bit on the RIDGID drill press, Model: DP15000, Model: 99329E0166.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5174

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2400.00 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:     On 04/25/2018 or about, employee(s) of C R Magnetics, located at 3500 Scarlet Oak Blvd., St. Louis, MO, had a Porter Cable bench grinder, Model: PCB525BG, S/N: 074523, which was missing a work rest for the abrasive wheel.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $3880

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:   On 04/25/2018 or about, employee(s) of C R Magnetics, located at 3500 Scarlet Oak Blvd., St. Louis, MO, had a Porter Cable bench grinder, Model: PCB525BG, S/N: 074523, which was missing a tongue guard for the abrasive wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343110839.