Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE DOE RUN COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE DOE RUN COMPANY in #1 CASTEEL DRIVE, VIBURNUM, MO 65566 (NAICS 331492). OSHA activity number 343111191.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The DOE RUN Company — free Get an email when a new federal OSHA severe-injury report for The DOE RUN Company is published. One employer, no account, unsubscribe in one click.
Establishment
THE DOE RUN COMPANY
Site address
#1 CASTEEL DRIVE
City
VIBURNUM
State
MO
ZIP
65566
Mailing
#1 CASTEEL DRIVE, VIBURNUM, MO 65566
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331492
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.212 A02

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 21, 2018
Penalty
Initial $10,163 · Current $7,114 Reduced
29 CFR 1910.212(a)(2): Guard on machine was not affixed to the machine or secured elsewhere when attachment to the machine was not possible:  At the time of the inspection, it was determined that on 4/24/2018 the access door to the ELDAN cable stripper was not secured to prevent the operator from opening the door while the machine was in operation.
Recent events (2)
  • — I (S) $7114.1
  • — Z (S) $10163

1910.212 A03 II

Serious Gravity 5 2 instances 5 exposed
Issued
Jun 21, 2018
Penalty
Initial $10,163 · Current $7,114 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  a) At the time of the inspection, the feed side of the ELDAN Cable Stripper was not guarded to prevent employees from reaching into the machine and the point of operation when the machine was operated in forward direction.  b) At the time of the inspection, the unload side of the ELDA Cable Stripper was not guarded to prevent employee from reaching into the machine and the point of operation when the machine was operated in reverse direction.
Recent events (2)
  • — I (S) $7114.1
  • — Z (S) $10163

1910.147 D

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 21, 2018
Abate by
Jul 18, 2018
Penalty
Initial $10,163 · Current $7,114 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  At the time of the inspection, it was determined that at the time of the accident on 4/24/2018 the authorized employee did not have adequate knowledge of the methods to control the hazardous energy and the machine was not shut down using procedures established for the machine. The energy isolating devices needed to control the energy to the machine were not operated exposing the employee to a hazardous energy source. Emergency stop buttons are not an approved method to isolate the electrical power supply to the cable slitter.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $7114.1
  • — Z (S) $10163

1910.147 C07 I A

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 21, 2018
Abate by
Jul 18, 2018
Penalty
Initial $10,163 · Current $7,114 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  At the time of the inspection, cable stripping machine operators were authorized to lockout equipment but had not received adequate training on the methods and means for energy isolation. Machine operator pulled e-stop on ELDAN Cable Stripper and began maintenance to remove the blade for sharpening. The energy source was not isolated exposing employees to the unexpected energization of the machine.   Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citations.
Recent events (2)
  • — I (S) $7114.1
  • — Z (S) $10163

View The DOE RUN Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343111191.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.