OSHA Inspection: TEXAS ELITE PRECAST & WELDING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TEXAS ELITE PRECAST & WELDING LLC in 2343 CARTWRIGHT ST. SUITE 101, DALLAS, TX 75212 (NAICS 327390). OSHA activity number 343111340.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas Elite Precast & Welding LLC — free Get an email when a new federal OSHA severe-injury report for Texas Elite Precast & Welding LLC is published. One employer, no account, unsubscribe in one click.
Site address
2343 CARTWRIGHT ST. SUITE 101
City
DALLAS
State
TX
ZIP
75212
Mailing
2343 CARTWRIGHT ST. SUITE 101, DALLAS, TX 75212
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
10
Ownership type
A

5 citations on file for this inspection.

1910.28 B03 I

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 20, 2018
Abate by
Jul 17, 2018
Penalty
Initial $3,326 · Current $3,326
29 CFR 1910.28(b)(3)(i): (3) Holes.  The employer must ensure: (i) Each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following:    a)    This violation occurred on or about and times prior to April 25, 2018, where employees were exposed to falling into an 8-foot hole.
Recent events (1)
  • — Z (S) $3326

1910.25 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 20, 2018
Abate by
Jul 17, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1910.25(b)(1): (1) Handrails, stair rail systems, and guardrail systems are provided in accordance with 29 CFR 1910.28:  a)  This violation was discovered April 25, 2018, at a job site located at 2343 Cartwright Street, Dallas, Texas; where at least one employee mixing concrete was exposed to falling.
Recent events (1)
  • — Z (S) $2217

1910.101 B

Serious Gravity 5 2 instances 8 exposed
Issued
Jun 20, 2018
Abate by
Jul 17, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6:  Section 3.4.4, Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over;    a)    Oxygen cylinders in the warehouse facility were stored upright but were not secured with a chain or strap to prevent them from falling;    b)    Acetylene cylinders in the warehouse facility were stored upright but were not secured with a chain or strap to prevent them from falling.
Recent events (1)
  • — Z (S) $2217

1910.178 L01 II

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 20, 2018
Abate by
Jul 17, 2018
Penalty
Initial $3,326 · Current $3,326
29 CFR 1910.178(l)(1)(ii):  The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck:     a)    This violation was discovered on April 25, 2018; where the employer did not ensure each operator had successfully complete the required training prior to permitting an employee to operate a power industrial truck.
Recent events (1)
  • — Z (S) $3326

1910.253 B04 III

Serious Gravity 10 1 instance 8 exposed
Issued
Jun 20, 2018
Abate by
Jul 17, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage wre not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:     a)    In the warehouse area, oxygen cylinders were stored closer than 20 feet from acetylene cylinders.
Recent events (1)
  • — Z (S) $3880

View Texas Elite Precast & Welding LLC's full OSHA safety record →