HOUSTON, TX —
OSHA Inspection: ATLAS DIAMOND, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ATLAS DIAMOND, INC. in 10550 WEST SAM HOUSTON PARKWAY SOUTH, HOUSTON, TX 77099 (NAICS 424490). OSHA activity number 343112488.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ATLAS DIAMOND, INC.
- Site address
- 10550 WEST SAM HOUSTON PARKWAY SOUTH
- City
- HOUSTON
- State
- TX
- ZIP
- 77099
- Mailing
- 10550 WEST SAM HOUSTON PARKWAY SOUTH, HOUSTON, TX 77099
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424490
- Employees
- 19
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.67 C02 V
- Issued
- Jul 31, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $4,656 · Current $2,793 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(v): A personal fall arrest or travel restraint system that meets the requirements of subpart I of this part were not worn or attached to the boom or basket when working from an aerial lift: a) At the warehouse, employees operating the CROWN Telescoping order picker (Model SP3520-30 Serial: 1A383334) were exposed to fall hazards of 20 feet while operating the equipment without personal fall arrests or restraining devices.
Recent events (2)
- — I (S) $2793
- — Z (S) $4656
1910.178 G02
- Issued
- Jul 31, 2018
- Abate by
- Aug 24, 2018
- Penalty
- Initial $3,326 · Current $1,996 Reduced
General-duty citation text
29 CFR 1910.178(g)(2): Battery changing and charging installations for industrial trucks were not provided with facilities for flushing and neutralizing spilled electrolyte: a) In the warehouse battery charging area, flushing stations were not provided near the Hobart Accu-charger (Model: 1050C3-18/Serial: 394CS11887). b) In the warehouse battery charging area, flushing stations were not provided near the GNB (Model: FER10012-750TI/Serial: 97F0467F). c) In the warehouse battery charging area, flushing stations were not provided near the CompuCharge Control (Model: FR12HK640 Serial: MPI-031614). d) In the warehouse battery charging area, flushing stations were not provided near the GNB (Model: SCR100-24-865T1 Serial: 96G0163S).
Recent events (2)
- — I (S) $1996
- — Z (S) $3326
1910.303 G01 I A
- Issued
- Jul 31, 2018
- Penalty
- Initial $3,326 · Current $1,996 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: a) At the warehouse office area, a SIEMENS electrical panel(120 volts 3Ph 125Amps) was obstructed by materials and was not equipped with the minimum safe working area.
Recent events (2)
- — I (S) $1996
- — Z (S) $3326
More inspections in this industry (NAICS 424490)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343112488.