NAPLES, FL —
OSHA Inspection: MOORE ROOFING & BUILDERS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of MOORE ROOFING & BUILDERS, INC. in 185 W. PAGO PAGO DRIVE, NAPLES, FL 34113 (NAICS 238160). OSHA activity number 343115457.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOORE ROOFING & BUILDERS, INC.
- Site address
- 185 W. PAGO PAGO DRIVE
- City
- NAPLES
- State
- FL
- ZIP
- 34113
- Mailing
- 1 FRONT STREET, NAPLES, FL 34113
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Aug 6, 2018
- Abate by
- Aug 30, 2018
- Penalty
- Initial $6,467 · Current $3,880 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, employees were exposed to a fall hazard while using a 4-tier scaffold that lacked planking. Instance 1: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, an employee was exposed to a fall hazard while hoisting roofing material from the 4th tier of a fabricated frame scaffold. Instance 2: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, two employees were exposed to a fall hazard while using the 4th tier of the scaffold that lacked planking to access a ladder leading to the roof. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $3880.2
- — Z (S) $6467
1926.451 C02
- Issued
- Aug 6, 2018
- Abate by
- Aug 30, 2018
- Penalty
- Initial $6,467 · Current $3,880 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, employees were exposed to a fall hazard while using a 4-tier scaffold that lacked base plates and mudsills. Instance 1: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, an employee was exposed to a fall hazard while hoisting roofing material from the 4th tier of a fabricated frame scaffold that lacked baseplates and mudsills. Instance 2: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, two employees were exposed to a fall hazard while using the 4th tier of the scaffold that lacked base plates and mudsills to access a ladder leading to the roof. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $3880.2
- — Z (S) $6467
1926.451 G01 VII
- Issued
- Aug 6, 2018
- Abate by
- Aug 30, 2018
- Penalty
- Initial $6,467 · Current $3,880 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, employees were exposed to a fall hazard while using a 4-tier scaffold that lacked guardrails. Instance 1: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, an employee was exposed to a fall hazard while hoisting roofing material from the 4th tier of a fabricated frame scaffold that lacked guardrails. Instance 2: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, two employees were exposed to a fall hazard while using the 4th tier of the scaffold that lacked guardrails to access a ladder leading to the roof. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $3880.2
- — Z (S) $6467
1926.451 E01
- Issued
- Aug 6, 2018
- Abate by
- Aug 30, 2018
- Penalty
- Initial $6,467 · Current $3,880 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. End frames were used as a means of access: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, employees were exposed to a fall hazard while climbing up the scaffold components of a 4-tier scaffold to access the top tier. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $3880.2
- — Z (S) $6467
1926.451 F03
- Issued
- Aug 6, 2018
- Abate by
- Aug 30, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 4/25/2018, at 185 Pago Pago Drive West, in the city of Naples, the employer did not ensure a competent person inspected the scaffold components prior to each work shift whereas the scaffold had several deficiencies exposing employees to fall hazards. Instance 1: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, an employee was exposed to a fall hazard while hoisting roofing material from the 4th tier of a fabricated frame scaffold that lacked baseplates, mudsills, guardrails, planking, and no access ladder. Instance 2: On or about 4/25/2018, at 181 W. Pago Pago Drive, in the city of Naples, two employees were exposed to a fall hazard while using the 4th tier of the scaffold that lacked baseplates, mudsills, guardrails, planking, and no access ladder. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Moore Roofing & Builders, INC.
View Moore Roofing & Builders, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343115457.