SCARBOROUGH, ME —
OSHA Inspection: ADJACENT BAKERY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADJACENT BAKERY in 5 LINCOLN AVE, SCARBOROUGH, ME 04074 (NAICS 311812). OSHA activity number 343118170.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADJACENT BAKERY
- Site address
- 5 LINCOLN AVE
- City
- SCARBOROUGH
- State
- ME
- ZIP
- 04074
- Mailing
- 5 LINCOLN AVE, SCARBOROUGH, ME 04074
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A03 II
- Issued
- May 24, 2018
- Abate by
- Jun 20, 2018
- Penalty
- Initial $2,772 · Current $1,108 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s) Production Room - The Benier dough divider's top swing cover safety interlock system was not operational.
Recent events (2)
- — I (S) $1108
- — Z (S) $2772
1910.263 F03
- Issued
- May 24, 2018
- Abate by
- May 31, 2018
- Penalty
- Initial $3,326 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.263(f)(3): The back of the divider was not completely covered or enclosed to guard against the hazard of moving parts. Production Room - The rear portion of the dough divider's intermediate proofer did not have any of the rear panels installed to prevent an employee from accessing the moving sections.
Recent events (2)
- — I (S) $1330
- — Z (S) $3326
1910.303 B07 IV
- Issued
- May 24, 2018
- Abate by
- Jun 20, 2018
- Penalty
- Initial $3,326 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. Production Area - Employees are exposed to an electrical arc hazard when plugging and unplugging the dough sheeter, due to the on/off switch being broken and always in the "on" position.
Recent events (2)
- — I (S) $1330
- — Z (S) $3326
More inspections in this industry (NAICS 311812)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343118170.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.