Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: B-W GRINDING SERVICES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of B-W GRINDING SERVICES, INC. in 5807 NUNN, HOUSTON, TX 77087 (NAICS 332710). OSHA activity number 343120648.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B-W Grinding Services, INC. — free Get an email when a new federal OSHA severe-injury report for B-W Grinding Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5807 NUNN
City
HOUSTON
State
TX
ZIP
77087
Mailing
5807 NUNN, HOUSTON, TX 77087
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
55
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 2 instances 50 exposed
Issued
Oct 25, 2018
Abate by
Nov 29, 2018
Penalty
Initial $6,596 · Current $3,958 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a)  At the facility where procedures were not developed and utilized for the control of hazardous energy when employees performed maintenance activities such as, but not limited to, changing grinding wheels and tooling machines.
Recent events (2)
  • — I (S) $3957.6
  • — Z (S) $6596

1910.147 D04 I

Serious Gravity 5 2 instances 50 exposed
Issued
Oct 25, 2018
Abate by
Nov 29, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a)  In the main building where a lockout or tagout device was not affixed to an energy isolating device when employees were changing the grinding wheel of machine number O15.  b)  In the main building where a lockout or tagout device was not affixed to an energy isolating device when employees were tooling machine number V1.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 25, 2018
Abate by
Nov 29, 2018
Penalty
Initial $4,398 · Current $2,639 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)  In the main building, where the rotating parts of machine #V1 were not guarded.
Recent events (2)
  • — I (S) $2638.8
  • — Z (S) $4398

1910.215 A02

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 25, 2018
Abate by
Nov 29, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:  a)  In the sales building, where the safety guard on Norton Grinder O1 did not cover the spindle end, nut, and flange projections.  a)  In the sales building, where the safety guard on Norton Grinder O4 did not cover the spindle end, nut, and flange projections.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 25, 2018
Penalty
Initial $2,803 · Current $1,682 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  In the main building, near machine #V1, where a relocatable power tap (RPT) was powered by an extension cord, creating a fire hazard.
Recent events (2)
  • — I (S) $1681.8
  • — Z (S) $2803

1910.304 G05

Serious Gravity 1 2 instances 4 exposed
Issued
Oct 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a)  In the main building, near machine V1, where a stand fan lacked its grounding pin.  b)  In the sales building, where a stand fan was lacked its grounding pin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View B-W Grinding Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343120648.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.