OSHA Inspection: JERNBERG INDUSTRIES, LLC DBA AAM METAL FORMING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JERNBERG INDUSTRIES, LLC DBA AAM METAL FORMING in 3908 S. PRINCETON AVENUE, CHICAGO, IL 60609 (NAICS 336390). OSHA activity number 343122958.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jernberg Industries, LLC DBA AAM Metal Forming — free Get an email when a new federal OSHA severe-injury report for Jernberg Industries, LLC DBA AAM Metal Forming is published. One employer, no account, unsubscribe in one click.
Site address
3908 S. PRINCETON AVENUE
City
CHICAGO
State
IL
ZIP
60609
Mailing
328 W. 40TH STREET, CHICAGO, IL 60609
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336390
Employees
325
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 5 1 instance 25 exposed
Issued
Sep 12, 2018
Abate by
Nov 9, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    a) On or about April 21, 2018, the employer failed to provide adequate training for employees performing service and/or maintenance activities to ensure the knowledge and skills required for the safe application, usage and removal of energy control devices were acquired. A maintenance employee sustained an amputation to the middle finger on the left hand during servicing of the Sumitomo/CIMF Press #2, Model No. TFPX300, Serial No. SSMA0600, while it was still operating, not de-energized and locked out.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9239

1910.147 D

Serious Gravity 10 1 instance 25 exposed
Issued
Sep 12, 2018
Abate by
Nov 9, 2018
Penalty
Initial $12,934 · Current $10,348 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):     a) Chicago Manufacturing Facility 2, Line 2 - On or about April 21, 2018, an employee was exposed to machine hazards associated with moving parts and pinch-points during troubleshooting maintenance activities on the Sumitomo/CIMF Press #2, Model No. TFPX300, Serial No. SSMA0600, which resulted in the amputation to the tip of the left hand middle finger.  The employer failed to implement energy control application steps as the machine was not shut down or turn off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $10348
  • — Z (S) $12934

1910.147 C06 I

Other-than-serious 1 instance 25 exposed
Issued
Sep 12, 2018
Abate by
Nov 9, 2018
Penalty
Initial $1,037 · Current $830 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) On or about April 21, 2018, authorized employees were required to perform servicing and/or maintenance to the Sumitomo/CIMF Press #2, Model No. TFPX300, Serial No. SSMA0600.  The employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard.
Recent events (2)
  • — I (O) $830
  • — Z (O) $1037

View Jernberg Industries, LLC DBA AAM Metal Forming's full OSHA safety record →