WILLIAMSVILLE, NY —
OSHA Inspection: ASHTON POTTER USA INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ASHTON POTTER USA INC. in 10 CURTWIRGHT DRIVE, WILLIAMSVILLE, NY 14221 (NAICS 323111). OSHA activity number 343127841.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASHTON POTTER USA INC.
- Site address
- 10 CURTWIRGHT DRIVE
- City
- WILLIAMSVILLE
- State
- NY
- ZIP
- 14221
- Mailing
- 10 CURTWIRGHT DRIVE, WILLIAMSVILLE, NY 14221
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 105
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.28 B03 I
- Issued
- May 30, 2018
- Penalty
- Initial $4,989 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items A through D of this section. a) On or about 05/01/18 at the Larger Coiler; employees worked on the grinder work platform at a height of 7 feet 9 inches and were exposed to a fall hazard when a 3 inch wide 24.75 inch height gap (hole) existed between the platform and the length of the grinder. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $3000
- — C (S) $4989
- — Z (S) $4989
1910.28 B03 IV
- Issued
- May 30, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(3)(iv): The employer did not ensure each employee was protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used. a) On or about 05/01/18 at the Larger Coiler; employees worked on the platform for the grinder and were exposed to a 7 foot fall hazard when entrance to the work platform was protected by a single chain. b) On or about 05/10/18 at the IDC Grinder; employees worked on the platforms on either side of the IDC grinder and were exposed to a 7 foot fall hazard when the entrance to each of the work platforms was protect by a single chain. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.28 C01
- Issued
- May 30, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(c)(1): Employer did not protect employees from falling objects by implementing one or more of the following: toeboards to prevent objects from falling to a lower level; a) On or about 05/01/18 at the Larger Coiler; employees worked on the grinder work platform and exposed employees working below to a struck by hazard when the walking surface did not have any protection to prevent objects from falling from the platform. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.36 G01
- Issued
- May 30, 2018
- Penalty
- Initial $4,989 · Current $0 Reduced
General-duty citation text
29 CFR 1910.36(g)(1): The ceiling of an exit route was not at least seven feet six inches (2.3 m) high and/or any projection from the ceiling reached a point less than six feet eight inches (2.0 m) from the floor. a) On or about 05/01/18 on the large coiler grinder work platform; employees were exposed to a struck by hazard when the support arms of the frame supporting the transformer projected into the exit route, at or about a height of 60 inches from the surface of the platform, partially blocking the exit from this work area. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (S) $4989
- — Z (S) $4989
1910.147 C04 I
- Issued
- May 30, 2018
- Abate by
- Jul 2, 2018
- Penalty
- Initial $6,652 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 05/01/18 in the Coiler area; employees performed service and maintenance activities on the coilers, such as but not limited to, cleaning the slitter blades, anvils, rollers, changing the slitter blades, positioning the anvils, general cleaning of the points of operation inside the coilers and were exposed to caught in and on hazards when the employer allowed them to use the emergency stop button and interlocked doors for protection against these hazards instead of the written equipment specific Lock-out/Tag-out procedures. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $6652
- — Z (S) $6652
1910.147 C07 I A
- Issued
- May 30, 2018
- Abate by
- Jul 2, 2018
- Penalty
- Initial $0 · Current $4,000
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation; a) On or about 05/01/18 in the Coiler area; employees performed service and maintenance activities on the coilers, such as but not limited to, cleaning the slitter blades, anvils, rollers, changing the slitter blades, positioning the anvils, general cleaning of the points of operation inside the coilers and were exposed to caught in and on hazards when the employer trained them to Affected level under their LOTO program and allowed them to use the emergency stop button and interlocked doors for protection against these hazards. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $4000
- — C (S) $0
- — Z (S) $0
1910.147 F03 I
- Issued
- May 30, 2018
- Abate by
- Jul 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft; a) On or about 05/01/18 in the Coiler area; more than one employee performed service and maintenance activities on the coilers, such as but not limited to, cleaning the slitter blades, anvils, rollers, changing the slitter blades, positioning the anvils, general cleaning of the points of operation inside the coilers and were exposed to caught in and on hazards when the employer allowed them to use the emergency stop button and interlocked doors for protection against these hazards instead of the requiring each employee place a personal lock on the energy isolation device(s). ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 323111)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343127841.