OSHA Inspection: LAPEYRE STAIR, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LAPEYRE STAIR, INC. in 5117 TOLER STREET, HARAHAN, LA 70123 (NAICS 332323). OSHA activity number 343129771.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lapeyre Stair, INC. — free Get an email when a new federal OSHA severe-injury report for Lapeyre Stair, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
LAPEYRE STAIR, INC.
Site address
5117 TOLER STREET
City
HARAHAN
State
LA
ZIP
70123
Mailing
5117 TOLER STREET, HARAHAN, LA 70123
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
30
Ownership type
A

1 citation on file for this inspection.

1910.147 C04 II

Serious Gravity 5 3 instances 2 exposed
Issued
Oct 11, 2018
Abate by
Oct 23, 2018
Penalty
Initial $5,497 · Current $3,298 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)[A], 29 CFR 1910.147(c)(4)(ii)[B], 29 CFR 1910.147(c)(4)(ii)[C], and 29 CFR 1910.147(c)(4)(ii)[D]:  On or about 05/02/2018, the employer did not ensure that written lock-out/tag-out procedures were machine specific for Cincinatti Press Brakes which utilizes both electric and pneumatic energy.  Procedures included specific steps for isolating and blocking, but did not include specific steps for a) shutting down and securing the machine to control hazardous energy; b) placing, removing, and transferring of locks/tags; and c) testing the machine to verify that lock-out/tag-out was effective.
Recent events (2)
  • — I (S) $3298.2
  • — Z (S) $5497

View Lapeyre Stair, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343129771.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.