Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOHN BEAN TECHNOLOGIES CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOHN BEAN TECHNOLOGIES CORPORATION in 19175 LEE ROAD SUITE 450, HUMBLE, TX 77338 (NAICS 488190). OSHA activity number 343131876.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch John Bean Technologies Corporation — free Get an email when a new federal OSHA severe-injury report for John Bean Technologies Corporation is published. One employer, no account, unsubscribe in one click.
Site address
19175 LEE ROAD SUITE 450
City
HUMBLE
State
TX
ZIP
77338
Mailing
19175 LEE ROAD SUITE 450, HUMBLE, TX 77338
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488190
Employees
245
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II B

Deleted Serious Gravity 10 1 instance 14 exposed
Issued
Jun 6, 2018
Abate by
Jun 25, 2018
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  On or about May 1, 2018, and times prior thereto, in Terminal Mechanical Rooms, where employees were exposed to struck-by hazards when performing repair on air handler units without energy control procedures that did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.
Recent events (3)
  • — R (S) $0
  • — C (S) $12934
  • — Z (S) $12934

1904.7 B03

Other-than-serious 1 instance 245 exposed
Issued
Jun 6, 2018
Abate by
Jun 25, 2018
Penalty
Initial $2,033 · Current $1,017 Reduced
29 CFR 1904.7(b)(3): The employer did not correctly classify the following work-related injuries or illnesses on the OSHA Form 300 or equivalent.     On May 1, 2018, the employer provided a 2018 OSHA Form 300 that did not correctly classify a work place injury.
Recent events (3)
  • — R (O) $1016.5
  • — C (O) $2033
  • — Z (O) $2033

1904.29 B02

Other-than-serious 2 instances 245 exposed
Issued
Jun 6, 2018
Abate by
Jun 25, 2018
Penalty
Initial $2,033 · Current $0 Reduced
29 CFR 1904.29(b)(2): The employer did not fill out or correctly fill out an OSHA Form 301 or equivalent for each recordable injury or illness.    On May 1, 2018:    a. The Employer provided a copy of the OSHA Form 301 for a work related injury, Case No. E7L9885, which was not correctly filled out.    b. The Employer provided a copy of the OSHA Form 301 for a work related injury, Case No. E7L9678, which was not correctly filled out.
Recent events (3)
  • — R (O) $0
  • — C (O) $2033
  • — Z (O) $2033

1904.32 A03

Other-than-serious 1 instance 245 exposed
Issued
Jun 6, 2018
Abate by
Jun 25, 2018
Penalty
Initial $2,033 · Current $0 Reduced
29 CFR 1904.32(a)(3): The employer did not certify an OSHA 300A Form or equivalent.    On May 1, 2018, the Employer provided a copy of the OSHA Form 300A for 2017 that was not certified.
Recent events (3)
  • — R (O) $0
  • — C (O) $2033
  • — Z (O) $2033

1910.303 B07 IV

Deleted Other-than-serious 1 instance 14 exposed
Issued
Jun 6, 2018
Abate by
Jun 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): Equipment with damaged parts that may adversely affect its safe operation or its mechanical strength, such as broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating parts shall not be used:  On or about May 1, 2018, and times prior thereto, in Mechanical Room CS1132M, where employees performed service and maintenance around an electrical motor relay box cover that was held in place with wire ties.
Recent events (3)
  • — R (O) $0
  • — C (O) $0
  • — Z (O) $0

View John Bean Technologies Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343131876.