Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HILCORP ALASKA, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HILCORP ALASKA, LLC in KING SALMON PLATFORM COOK INLET, NIKISKI, AK 99635 (NAICS 213111). OSHA activity number 343133369.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hilcorp Alaska, LLC — free Get an email when a new federal OSHA severe-injury report for Hilcorp Alaska, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
HILCORP ALASKA, LLC
Site address
KING SALMON PLATFORM COOK INLET
City
NIKISKI
State
AK
ZIP
99635
Mailing
3800 CENTERPOINT DR. SUITE 100, ANCHORAGE, AK 99503
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
12
Ownership type
A

2 citations on file for this inspection.

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
May 10, 2018
Abate by
Jun 8, 2018
Penalty
Initial $4,712 · Current $3,770 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    King Salmon Platform, Maintenance Shop:  On or about 01 May 2018 and times prior thereto, the Jet Floor Standing Drill Press, Model # JDP-20MF was not was not secured to a fixed location.  This condition exposed employees to a struck by hazard.
Recent events (2)
  • — I (S) $3770
  • — Z (S) $4712

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
May 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    King Salmon Platform, Drive Room:  On or about 01 May 2018and times prior thereto, a 30 foot yellow extension cord exhibited strain relief.  This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Hilcorp Alaska, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343133369.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.