TEANECK, NJ —
OSHA Inspection: VP CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VP CONSTRUCTION LLC in 692 MILDRED ST, TEANECK, NJ 07666 (NAICS 238170). OSHA activity number 343135554.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VP CONSTRUCTION LLC
- Site address
- 692 MILDRED ST
- City
- TEANECK
- State
- NJ
- ZIP
- 07666
- Mailing
- 12 MOUNTAIN RD, WAYNE, NJ 07470
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 F06
- Issued
- Jun 1, 2018
- Penalty
- Initial $3,880 · Current $1,940 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. For Insulated lines - minimum distance of 3 feet when line is less than 300 V a) Exterior of Building - Scaffold Driveway - Vandelinda Ave.: Employee engaged in siding activities from a pump jack scaffold platform that was less than one foot from a live electric residential service, was exposed to electric hazards, on or about 5/2/18.
Recent events (2)
- — I (S) $1940
- — Z (S) $3880
1926.451 G01
- Issued
- Jun 1, 2018
- Penalty
- Initial $3,880 · Current $1,940 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) Exterior of Building - Scaffold Driveway - Vandelinda Ave.: Employee without proper means of fall protection, engaged in siding activities from a pump jack scaffold platform, was exposed to fall hazards of approximately 11 feet, on or about 5/2/18.
Recent events (2)
- — I (S) $1940
- — Z (S) $3880
More inspections at VP Construction LLC
View VP Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343135554.