BATAVIA, OH —
OSHA Inspection: RONALD G. LANE, SR. L.L.C.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RONALD G. LANE, SR. L.L.C. in 1242 CREEKWOOD CT., BATAVIA, OH 45103 (NAICS 238140). OSHA activity number 343138418.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RONALD G. LANE, SR. L.L.C.
- Site address
- 1242 CREEKWOOD CT.
- City
- BATAVIA
- State
- OH
- ZIP
- 45103
- Mailing
- 8674 GLENROSE LANE, CINCINNATI, OH 45244
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.451 A01
- Issued
- Jun 22, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1926.451(a)(1): Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. On April 11, 2018, in the rear of a two story home, 1242 Creekwood Ct. Batavia, two employees were working from a wood plank platform on a welded frame scaffold, when an employee stepped on a knot in the wood planking causing the wood planking to break into two pieces and caused the employee to fall 13 ft. 7 inch to the ground.
Recent events (2)
- — I (S) $2772
- — Z (S) $2772
1926.451 B01
- Issued
- Jun 22, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $2,772 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: On April 11, 2018, at the rear of 1242 Creekwood Ct. Batavia, a residential home, two employees were exposed to a 15 ft. fall hazard from the platform lacking two, 2" x 10" planks to complete the working platform of a welded frame scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $2772
1926.451 B03
- Issued
- Jun 22, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $2,772 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(3): Except as provided in paragraphs (b)(3)(i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling. On April 11, 2018, at the rear of 1242 Creekwood Ct., Batavia, a residential home, two employees on a wooden plank platform on a welded frame scaffold were exposed to a 13 ft. 7 inch fall hazard by the scaffold located between 27" and 29" from the face of the wall without a guardrail system erected and/or personal fall arrest systems used.
Recent events (2)
- — I (S) $0
- — Z (S) $2772
1926.451 C02
- Issued
- Jun 22, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $1,663 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. On April 11, 2018, at the rear of 1242 Creekwood Ct. Batavia, a two story residential home, a welded frame scaffold was erected on dirt ground on the Southeast end of the rear of the home, where both ends were missing mud sills and the end pole was located on the concrete deck was missing a base plate.
Recent events (2)
- — I (S) $0
- — Z (S) $1663
1926.451 F03
- Issued
- Jun 22, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $2,772 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. On April 11, 2018, the employer had not ensured that a competent person had inspected the welded frame scaffold for defects at 1242 Creekwood Ct. Batavia, prior to two employees beginning work on the scaffold to remove rotten and damaged soffit from the rear of a two-story home.
Recent events (2)
- — I (S) $0
- — Z (S) $2772
1926.451 F07
- Issued
- Jun 22, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $2,772 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person. On April 10, 2018, at the rear of 1242 Creekwood Ct. Batavia, a two story home, two employees were erecting a welded frame scaffold not under the supervision and direction a competent person qualified in scaffold erection.
Recent events (2)
- — I (S) $0
- — Z (S) $2772
1926.451 G01
- Issued
- Jun 22, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $3,880 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. On April 11, 2018, at the rear of a residential home at 1242 Creek Ct., Batavia, two employees on a welded frame scaffold were exposed to an approximately 13 ft. 7 inch fall hazard from the lack of fall protection installed on the scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1926.454 A
- Issued
- Jun 22, 2018
- Abate by
- Jul 26, 2018
- Penalty
- Initial $2,772 · Current $1,940 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable: On April 11, 2018, at the rear of 1242 Creekwood Ct. Batavia, a two story residential home, two employees involved with the erection of a welded frame scaffold and the removal of soffit from the home's eave had not received training from the employee of how to recognize hazards while erecting the scaffold and minimize fall hazards while working from the working platform of the scaffold.
Recent events (2)
- — I (S) $1940.4
- — Z (S) $2772
1904.39 A02
- Issued
- Jun 22, 2018
- Abate by
- Jul 5, 2018
- Penalty
- Initial $2,772 · Current $1,940 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA. The employer did not report an in-patient hospitalization within 24 hours for a work-related injury occurring at 1242 Creekwood Ct. Batavia, on April 11, 2018 until April 27, 2018.
Recent events (2)
- — I (O) $1940.4
- — Z (O) $2772
More inspections in this industry (NAICS 238140)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343138418.