JERSEY CITY, NJ —
OSHA Inspection: NICHOLAS HOME IMPROVEMENT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NICHOLAS HOME IMPROVEMENT, LLC in 997 SUMMIT AVENUE, JERSEY CITY, NJ 07307 (NAICS 238350). OSHA activity number 343142089.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NICHOLAS HOME IMPROVEMENT, LLC
- Site address
- 997 SUMMIT AVENUE
- City
- JERSEY CITY
- State
- NJ
- ZIP
- 07307
- Mailing
- 111 RANDOLPH AVENUE, JERSEY CITY, NJ 07305
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 F06
- Issued
- Jun 5, 2018
- Penalty
- Initial $2,439 · Current $2,439
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines. a) Front and side of house- Employees were working on a scaffold and a ladder that was less than two feet away from energized power lines; on or about 5/7/18.
Recent events (1)
- — Z (S) $2439
1926.451 G01
- Issued
- Jun 5, 2018
- Penalty
- Initial $4,268 · Current $4,268
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. a) Front of house- Employees were exposed to a fall of approximately 16 ft while working on a pump jack scaffold without any fall protection; on or about 5/7/18.
Recent events (1)
- — Z (S) $4268
1926.1053 B08
- Issued
- Jun 5, 2018
- Penalty
- Initial $2,439 · Current $2,439
General-duty citation text
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder. a) On the side of the house- Employees were using a ladder that could be displaced by workplace activities and was not secured to prevent accidental displacement; on or about 5/17/18.
Recent events (1)
- — Z (S) $2439
1926.1053 B01
- Issued
- Jun 5, 2018
- Penalty
- Initial $6,098 · Current $6,098
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Side of the house- Employees were accessing a ladder that did not extend 3 feet above the platform of the scaffold; on or about 5/9/18. Nicholas Home Improvement, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.1053(b)(1), which was contained in OSHA inspection number 1108987, citation number 1, item number 3, and was affirmed as a final order on 11/08/16 with respect to a workplace located at 417 Fairmount Ave., Jersey City, NJ 07304.
Recent events (1)
- — Z (R) $6098
More inspections at Nicholas Home Improvement, LLC
View Nicholas Home Improvement, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343142089.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.