Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MECHANICAL PLASTICS CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MECHANICAL PLASTICS CORPORATION in 110 RICHARDS AVENUE, NORWALK, CT 06854 (NAICS 493110). OSHA activity number 343143517.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mechanical Plastics Corporation — free Get an email when a new federal OSHA severe-injury report for Mechanical Plastics Corporation is published. One employer, no account, unsubscribe in one click.
Site address
110 RICHARDS AVENUE
City
NORWALK
State
CT
ZIP
06854
Mailing
110 RICHARDS AVENUE, NORWALK, CT 06854
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
30
Ownership type
A

2 citations on file for this inspection.

1910.178 L04 III

Serious Gravity 5 1 instance 3 exposed
Issued
May 15, 2018
Abate by
Jul 2, 2018
Penalty
Initial $5,174 · Current $3,622 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  WAREHOUSE:  The performance of the operators of the powered industrial trucks was not evaluated at least once every three years.
Recent events (2)
  • — I (S) $3621.8
  • — Z (S) $5174

1910.178 P01

Serious Gravity 5 2 instances 3 exposed
Issued
May 15, 2018
Abate by
Jul 2, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  WAREHOUSE: The following powered industrial trucks (PITs) had defects and were not removed from service:       1.   Crown powered industrial truck; not equipped with a horn and a back up alarm or devices.    2.   Yale 442 powered industrial truck; right back up light bulb not operable.