Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: CALIFORNIA COMMERCIAL ROOFING SYSTEMS, INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of CALIFORNIA COMMERCIAL ROOFING SYSTEMS, INC. in 17225 JERSEY AVE., LEMOORE, CA 93245 (NAICS 238160). OSHA activity number 343143533.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch California Commercial Roofing Systems, INC. for free Get an email when a new federal OSHA severe-injury report for California Commercial Roofing Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
17225 JERSEY AVE.
City
LEMOORE
State
CA
ZIP
93245
Mailing
2747 SHERWIN AVE. # 8, VENTURA, CA 93003
Inspection type
Programmed Related (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
13
Ownership type
Private (A)

2 citations on file for this inspection.

1926.405 G02 IV

Serious Gravity 1 1 instance 6 exposed
Issued
May 17, 2018
Abate by
Jun 14, 2018
Penalty
Initial $2,217 · Current $1,663 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    Casino Warehouse Rooftop: Strain relief was not provided to a white extension cord, the outer sheathing of the extension cord was pulled back exposing the inner conductors to physical damage. The cord energized a DeWALT electric drill.
Recent events (2)
  • · I (S) $1662.75
  • · Z (S) $2217

1926.501 B04 I

Serious Gravity 10 1 instance 6 exposed
Issued
May 17, 2018
Abate by
Jun 14, 2018
Penalty
Initial $5,174 · Current $2,770 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:    Casino Warehouse Rooftop : Employees were not provided with fall protection while engaged in roofing work around skylights. The employees were exposed to 25 and 15 foot falls to lower levels.