LEMOORE, CA ·
OSHA Inspection: TACHI PALACE HOTEL & CASINO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TACHI PALACE HOTEL & CASINO in 17225 JERSEY AVE., LEMOORE, CA 93245 (NAICS 721120). OSHA activity number 343143590.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TACHI PALACE HOTEL & CASINO
- Site address
- 17225 JERSEY AVE.
- City
- LEMOORE
- State
- CA
- ZIP
- 93245
- Mailing
- 17225 JERSEY AVE., LEMOORE, CA 93245
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 1350
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 10, 2018
- Penalty
- Initial $6,282 · Current $2,804 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Wood Working Shop: The Sawstop 10 inch table saw was not provided with the blade guards to protect the operator from hazards created by point of operation.
Recent events (2)
- · I (S) $2803.5
- · Z (S) $6282
1910.305 B01 II
- Issued
- Jul 10, 2018
- Penalty
- Initial $4,712 · Current $2,804 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Wood Working Shop: Live electrical parts were exposed in the electrical panel due to missing circuit breaker # 37. Employees were exposed to electrical hazards.
Recent events (2)
- · I (S) $2803.5
- · Z (S) $4712
1910.253 B04 III
- Issued
- Jul 10, 2018
- Penalty
- Initial $4,712 · Current $2,804 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. Kitchen Tech Room: Oxygen cylinders in storage were not separated from flammable acetylene cylinders as required. Employees were exposed to projectile and explosion hazards.
Recent events (2)
- · I (S) $2803.5
- · Z (S) $4712
More inspections in this industry (NAICS 721120)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343143590.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.