EVERETT, MA —
OSHA Inspection: LUND REBAR SERVICES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LUND REBAR SERVICES INC. in HORIZON WAY, EVERETT, MA 02149 (NAICS 238120). OSHA activity number 343145447.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LUND REBAR SERVICES INC.
- Site address
- HORIZON WAY
- City
- EVERETT
- State
- MA
- ZIP
- 02149
- Mailing
- 41 PUTNAM STREET, WINTHROP, MA 02152
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 167
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.150 A01
- Issued
- Jul 25, 2018
- Penalty
- Initial $7,068 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.150(a)(1): The employer did not develop and maintain a fire protection program to be followed throughout all phases of construction and demolition work, and/or did not provide for the firefighting equiment as specified in this subpart: Hotel 28th Floor: On or about April 30, 2018, the employer did not provide firefighting equipment.
Recent events (2)
- — I (S) $3000
- — Z (S) $7068
1926.150 C01 I
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof:(a Hotel 28th Floor: On or about April 30, 2018, the employer did not provide a minimum type 2A extinguisher for each 3000 square feet of work area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.150 C01 VI
- Issued
- Jul 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite Hotel 28th Floor: On or about April 30, 2018, the employer did not provide a minimum 10B fire extinguisher where flammable liquids, flammable gases and where gasoline powered equipment was being operated.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B04 II
- Issued
- Jul 25, 2018
- Penalty
- Initial $5,654 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers Hotel 28th Floor: on or about April 30, 2018, employees were exposed to open holes in the concrete walking working surface that were not covered.
Recent events (2)
- — I (S) $3000
- — Z (S) $5654
More inspections in this industry (NAICS 238120)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343145447.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.