BRIGHTON, CO —
OSHA Inspection: COLORADO HOMES LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COLORADO HOMES LLC in 144TH AVE AND CHAMBERS ST, BRIGHTON, CO 80601 (NAICS 236115). OSHA activity number 343146841.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLORADO HOMES LLC
- Site address
- 144TH AVE AND CHAMBERS ST
- City
- BRIGHTON
- State
- CO
- ZIP
- 80601
- Mailing
- 6460 S. QUEBEC ST., CENTENNIAL, CO 80111
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 50
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 J02
- Issued
- Aug 21, 2018
- Abate by
- Sep 10, 2018
- Penalty
- Initial $5,174 · Current $3,100 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: (a) Colorado Homes, LLC, 1417 Indigo Dr., Brighton, CO 80601: On or before May 8, 2018, the exposing employer did not ensure that employees working inside a trench were protected from injury, in that the spoils pile was placed at the edge of the trench on the north side and less than two feet from the edge on the south side. The trench was approximately 6 feet wide at the opening, 12 feet deep, and 75 feet in length. This condition exposed the employees to the hazard of spoil pile material falling into the excavation or causing the excavation walls to collapse.
Recent events (2)
- — I (O) $3100
- — Z (S) $5174
1926.651 K01
- Issued
- Aug 21, 2018
- Abate by
- Sep 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres and or other hazardous conditions: (a) Colorado Homes, LLC, 1417 Indigo Dr., Brighton, CO 80601: On or before May 8, 2018, the employer did not ensure that daily inspections of the excavation, that measured approximately 12 feet in depth, and the adjacent area were made by the competent person for evidence of a situation that could have resulted in a hazardous condition, in that the competent person did not identify the lack of an appropriate protective system or did not take prompt corrective action to eliminate the cave-in hazard. This condition exposed employees to a crushing hazard by excavation wall cave-in.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Aug 21, 2018
- Abate by
- Sep 10, 2018
- Penalty
- Initial $6,467 · Current $3,700 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): (a) Colorado Homes, LLC, 1417 Indigo Dr., Brighton, CO 80601: On or before May 8, 2018, the exposing employer did not ensure that employees working inside a trench with vertical walls were protected from cave-in, in that an employee worked inside the trench at a location that measured approximately 12 feet in depth without using a protective system. The trench measured approximately 6 feet wide. This condition exposed the employee to a crushing hazard by excavation wall cave-in.
Recent events (2)
- — I (S) $3700
- — Z (S) $6467
More inspections at Colorado Homes LLC
View Colorado Homes LLC's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343146841.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.