ATLANTA, GA —
OSHA Inspection: STRUCTURED HOME SERVICES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STRUCTURED HOME SERVICES, LLC in 2050 CHESHIRE BRIDGE ROAD, ATLANTA, GA 30324 (NAICS 238160). OSHA activity number 343148151.
Where did this inspection happen?
- Establishment
- STRUCTURED HOME SERVICES, LLC
- Site address
- 2050 CHESHIRE BRIDGE ROAD
- City
- ATLANTA
- State
- GA
- ZIP
- 30324
- Mailing
- 1104 MCDONOUGH PLACE, MCDONOUGH, GA 30253
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2772.00 · Current $1663.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) New apartment construction located at 2050 Cheshire Bridge Road, Roof on building 2000: On or about 05/09/2018, and at times prior, the employer exposed employees to fall hazards of 73-feet to the lower level, in that employees working on a 5/12 pitched roof installing roofing felt were not protected from falls to the lower level as fall protection systems were not connected to the anchor provided with the system and employees failed to connect lanyards to the D-ring on the full body harnesses being worn.
Recent events (2)
- — I (S) $1663.2
- — Z (S) $2772
1926.503 A02 II
- Issued
- Penalty
- Initial $2772.00 · Current $1663.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used: (a) New apartment construction located at 2050 Cheshire Bridge Road, Roof on Building 2000: On or about 05/09/2018 and at times prior, the employer exposed employees to fall hazards of 73-feet, in that the employer failed to train employees correct procedures to erect, maintain and inspect personal fall protection systems. Anchors and life-lines were not used according to the manufacturer's specifications.
Recent events (2)
- — I (S) $1663.2
- — Z (S) $2772
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343148151.