CHICAGO, IL —
OSHA Inspection: CARDINAL PALLET CO.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CARDINAL PALLET CO. in 505 WEST 43RD STREET, CHICAGO, IL 60609 (NAICS 321920). OSHA activity number 343150413.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARDINAL PALLET CO.
- Site address
- 505 WEST 43RD STREET
- City
- CHICAGO
- State
- IL
- ZIP
- 60609
- Mailing
- 505 WEST 43RD STREET, CHICAGO, IL 60609
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 30
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C07 I
- Issued
- Aug 28, 2018
- Abate by
- Sep 24, 2018
- Penalty
- Initial $9,054 · Current $5,432 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices. a) North Building Production Area - On or about May 2, 2018, the employer failed to provide adequate training for employees performing service and/or maintenance activities to ensure the knowledge and skills required for the safe application, usage and removal of energy control devices were acquired. A laborer/saw operator sustained a severe laceration to the back of the left hand while attempting to clear wood from near the sawblade of an operating Newman KM16 Trim Saw.
Recent events (2)
- — I (S) $5432
- — Z (S) $9054
1910.147 D
- Issued
- Aug 28, 2018
- Abate by
- Sep 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)(6): a) North Building Production Area - On or about May 2, 2018, employees were exposed to machine hazards associated with moving parts when clearing wood from near the sawblade of the Newman KM16 Trim Saw. The employer failed to implement energy control application steps as the machine was not shut down or turn off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F03 II D
- Issued
- Aug 28, 2018
- Abate by
- Sep 24, 2018
- Penalty
- Initial $6,467 · Current $3,880 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: a) North Building Production Area - On or about May 10, 2018, the employer failed to ensure that each of the three employees involved in the servicing task of changing the sawblade(s) on the Newman KM16 Trim Saw affixed a personal lockout device (lock) onto a group lockout device. Only one lock was used to lockout the trim saw, thereby the two other employees assisting with changing the sawblade(s) were exposed to hazards associated with the unintentional startup of the saw.
Recent events (2)
- — I (S) $3880
- — Z (S) $6467
1910.147 C06 I
- Issued
- Aug 28, 2018
- Abate by
- Sep 24, 2018
- Penalty
- Initial $726 · Current $436 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) North Building Production Area - On or about May 10, 2018, authorized employees were required to perform servicing and/or maintenance on the Newman KM16 Trim Saw, Whirlwind Model 212 Cutoff Saw, Hazelthorn A10 Single Notcher and other operating equipment. The employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard.
Recent events (2)
- — I (O) $436
- — Z (O) $726
More inspections at Cardinal Pallet CO.
View Cardinal Pallet CO.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343150413.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.