OSHA Inspection: R.C.M. INDUSTRIES DBA INLAND DIE CASTING COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of R.C.M. INDUSTRIES DBA INLAND DIE CASTING COMPANY in 161 CARPENTER AVE., WHEELING, IL 60090 (NAICS 331524). OSHA activity number 343152161.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.C.M. Industries DBA Inland DIE Casting Company — free Get an email when a new federal OSHA severe-injury report for R.C.M. Industries DBA Inland DIE Casting Company is published. One employer, no account, unsubscribe in one click.
Site address
161 CARPENTER AVE.
City
WHEELING
State
IL
ZIP
60090
Mailing
161 CARPENTER AVE., WHEELING, IL 60090
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331524
Employees
221
Ownership type
A

5 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 5, 2018
Abate by
Dec 3, 2018
Penalty
Initial $11,086 · Current $6,172 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and the requirements of this standard are being followed:         a) On May 10, 2018, a periodic inspection of the energy control procedure(s) was not performed at least annually to identify potential deficiencies and to ensure skill proficiency was maintained while utilizing the procedure(s).
Recent events (2)
  • — I (S) $6172
  • — Z (S) $11086

1910.332 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 5, 2018
Abate by
Feb 28, 2019
Penalty
Initial $12,934 · Current $8,000 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments.    a) Trim Press Department - On or about May 7, 2018, the employer did not ensure that employee(s) performing electrical work were trained and familiar with safety-related work practices. An employee came in contact with live electrical equipment and suffered an electrical shock when installing additional light lamps on Trim Press #16.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $12934

1910.333 A

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 5, 2018
Abate by
Feb 28, 2019
Penalty
Initial $12,934 · Current $8,000 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:    a) Trim Press Department - On or about May 7, 2018, the employer did not ensure that employee(s) used safety-related work practices to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when performing electrical work such as installing additional light lamps on Trim Press #16.  An employee came in contact with live electrical equipment during installation of the lighting and suffered an electrical shock.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $12934

1910.335 A01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 5, 2018
Abate by
Feb 28, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    a) Trim Press Department - On or about May 7, 2018, the employer did not ensure that an employee working on installing additional light lamps on Trim Press #16, was provided the appropriate personal protective equipment for electrical hazards. An employee installing lighting suffered an electrical shock when working without appropriate personal protective equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 B02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 5, 2018
Abate by
Feb 28, 2019
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:    a) Trim Press Department - On or about May 7, 2018, the employer did not maintain a copy of the written safety related work practice procedures outlined in 29 CFR 1910.333(b)(2) for employees performing work on or near exposed energized parts such as installing lighting on a Trip Press.  An employee suffered an electrical shock when he came into contact with live electrical equipment during installation of the lamps.