Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EDILZER VASQUEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EDILZER VASQUEZ in 704 NW68TH STREET, BENTONVILLE, AR 72716 (NAICS 238160). OSHA activity number 343153201.

Watch Edilzer Vasquez — free Get an email when a new federal OSHA severe-injury report for Edilzer Vasquez is published. One employer, no account, unsubscribe in one click.
Establishment
EDILZER VASQUEZ
Site address
704 NW68TH STREET
City
BENTONVILLE
State
AR
ZIP
72716
Mailing
601 WEST EASY, APT 6612, ROGERS, AR 72756
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $1000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    For the employees performing roofing activities on or about May 10, 2018 and times prior there to, the employer did not use fall protection when working 6 feet or greater above the ground.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    For the employee performing roofing activities on or about May 10, 2018 and times prior there to, the employer did not extend the ladder at least 3 feet above the roof edge.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2217

1926.1053 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).   For the employees using the extension ladder to access the roof on or about May 10, 2018 and times prior there to, the employer did not set the ladder at an angle of approximately 75 1/2 degrees from horizontal or one foot horizontal for every four feet vertical.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343153201.