SAN ANTONIO, TX —
OSHA Inspection: ICARUS SIGN & GRAPHIC CO., INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ICARUS SIGN & GRAPHIC CO., INC. in 5419 BANDERA SUITE 706, SAN ANTONIO, TX 78238 (NAICS 321999). OSHA activity number 343165627.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ICARUS SIGN & GRAPHIC CO., INC.
- Site address
- 5419 BANDERA SUITE 706
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78238
- Mailing
- 5419 BANDERA SUITE 706, SAN ANTONIO, TX 78238
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 13, 2018
- Abate by
- Jul 23, 2018
- Penalty
- Initial $1,663 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Shop Area: On or about May 17, 2018, and at times prior thereto, employees were exposed to caught-in hazards while using a Hitachi C10FR Table Saw without a guard installed.
Recent events (2)
- — I (S) $0
- — Z (S) $1663
1910.303 G01 I
- Issued
- Jul 13, 2018
- Abate by
- Jul 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i): Sufficient access and working space was not provided for circuit breaker panels to permit ready and safe operation and maintenance: Northeast side of shop area: On or about May 17, 2018, and at times prior thereto, in the event of an emergency, employees were exposed to a delayed access from workbench placed directly in front of an electrical panel.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Jul 13, 2018
- Abate by
- Jul 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met: Shop Area: On or about May 17, 2018, and at times prior thereto, employees were exposed to chemical hazards: the employer did not have a written hazard communication program for employees who were required to use products such as, but not limited to, Dupli-Color Omni-Pak Aerosol Paints and Rust-oleum Crystal Clear Enamel.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 321999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343165627.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.