COLORADO SPRINGS, CO —
OSHA Inspection: INLAND COLORADO LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of INLAND COLORADO LLC in 7011 FOREST MEADOWS AVE, COLORADO SPRINGS, CO 80922 (NAICS 236116). OSHA activity number 343168308.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INLAND COLORADO LLC
- Site address
- 7011 FOREST MEADOWS AVE
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80922
- Mailing
- 120 W CATALDO AVE, SPOKANE, WA 99201
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.502 B01
- Issued
- Jun 13, 2018
- Abate by
- Jun 21, 2018
- Penalty
- Initial $5,174 · Current $4,000 Reduced
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: (a) On or about May 8, 2018, and at times prior, Inland Group, as the controlling employer, did not ensure employees of subcontractors, Cruz Siding & Remodelations and J and A Painting, LLC, were protected from fall hazards where the top rail on the second story stairway landing of building G measured 36.5 inches. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $4000
- — Z (S) $5174
1926.502 J01
- Issued
- Jun 13, 2018
- Abate by
- Jun 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(j)(1): Toeboards were not erected along the edge of the overhead walking/working surface for a distance sufficient to protect employees below: (a) On or about May 8, 2018, and at times prior, Inland Group, as the controlling employer, did not ensure employees of sub-contractors, Cruz Siding & Remodelations and J and A Painting, LLC, were protected from struck by hazards throughout building G and building H in that toeboards were not installed along the edge of overhead working surfaces. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1052 A06
- Issued
- Jun 13, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(a)(6): All parts of stairways were not free of protruding projections: (a) On or about May 8, 2018, Inland Group, as the controlling employer, did not insure that the installed handrails in the ascending and descending stairways of Building G were free of protruding projection (nails) thus exposing employees of subcontractors Cruz Siding & Remodelations and J and A Painting, LLC, to punctures from protruding projections. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1052 C04 I
- Issued
- Jun 13, 2018
- Abate by
- Jun 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(4)(i): Midrails used in stairrail systems were not located at a height midway between the top edge of the stairrail system and the stairway steps: (a) On or about May 8, 2018, and at times prior, Inland Group, as the controlling employer, did not ensure employees of subcontractors, Cruz Siding and Remodelations and J and A Painting, LLC, were protected from fall hazards where midrails throughout building G and building H were not located at a height midway between the top stairrail and stairway steps. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1052 C06
- Issued
- Jun 13, 2018
- Abate by
- Jun 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(6): The height of handrails was less than 30 inches (76 cm) or greater than 37 inches (94 cm) from the upper surface of the handrail to the surface of the tread in line with the face of the riser at the forward edge of the tread: (a) On or about May 8, 2018, and at times prior, Inland Group, as the controlling employer, did not ensure employees of subcontractors, Cruz Siding and Remodelations and J and A Painting, LLC were protected from fall hazards where handrails throughout building G and building H were greater than 37 inches from the surface of the tread. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.25 A
- Issued
- Jun 13, 2018
- Abate by
- Jun 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures. (a) On or about May 08, 2018, and at times prior, the controlling employer exposed employees of subcontractors, Cruz Siding & Remodelations and J and A Painting, LLC, to lacerations, slips, trips and falls due to inadequate housekeeping, including, but not limited to debris and other various materials in the passageways, stairways, and work areas. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Inland Colorado LLC