MARSHALL, TX —
OSHA Inspection: AMERICAN TIETEK LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AMERICAN TIETEK LLC in 429 S. MEMORY LANE, MARSHALL, TX 75670 (NAICS 326199). OSHA activity number 343168720.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN TIETEK LLC
- Site address
- 429 S. MEMORY LANE
- City
- MARSHALL
- State
- TX
- ZIP
- 75670
- Mailing
- 429 S. MEMORY LANE, MARSHALL, TX 75670
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 29, 2018
- Abate by
- Sep 25, 2018
- Penalty
- Initial $5,174 · Current $3,104 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer does not furnish to each of his employees employment and a place of employment which are free from recognized struck-by and/or crushed-by hazards that are causing or likely to cause death or serious physical harm to his employees who operated overhead underhung (electric) hoists were exposed to struck-by and/or crushed by hazards: (a) In the Raw Materials / Non-Melt Area, the employer did not ensure that each actuator on the pendant control box was clearly marks or identified with its function; (b) In the Raw Materials / Non-Melt Area, the employer did not ensure that each overhead underhung (electric) hoists were clearly marked with its rated capacity.
Recent events (2)
- — I (S) $3104.4
- — Z (S) $5174
1910.305 G02 III
- Issued
- Aug 29, 2018
- Abate by
- Sep 25, 2018
- Penalty
- Initial $2,956 · Current $1,774 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Raw Material/ Non Melt Area, the cord servicing the overhead underhung (electrical) hoist #4 was not connected to a device so that strain relief was provided exposing employees to electrical hazards; (b) Raw Material/ Non Melt Area, the cord servicing the overhead underhung (electrical) hoist #6 was not connected to a device so that strain relief was provided exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1773.6
- — Z (S) $2956
More inspections in this industry (NAICS 326199)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343168720.