OSHA Inspection: NICOL CONSTUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NICOL CONSTUCTION, LLC in 630 14TH. ST., NE, WASHINGTON, DC 20002 (NAICS 236116). OSHA activity number 343170346.

Watch Nicol Constuction, LLC — free Get an email when a new federal OSHA severe-injury report for Nicol Constuction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
630 14TH. ST., NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
5206 EAST CAPITOL ST., NE, WASHINGTON, DC 20019
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1600.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets:       a)  630 14th St., NE, Street Exposure, Ground level - On or about May 8, 2018, a carpenter working on the ground was not provided head protection where he was exposed to falling tools and materials while another employee was working above him on a pump jack scaffold.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2217

1926.451 B05 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $2000.00 Reduced
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end:     a)  630 14th St., NE, Street Exposure - On or about May 8, 2018, two carpenters were exposed to a 30 foot fall from a 24 foot fabricated scaffold platform which projected 6 feet over its last horizontal support of a pump jack scaffold platform's south end and 4 feet over its last horizontal support on the platform's north end.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2772

1926.1053 A07

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2800.00 Reduced
29 CFR 1926.1053(a)(7): Ladders not designed for such use were tied or fastened together to provide longer sections:      a)  630 14th St., NE, Street Exposure - On or about May 8, 2018, three carpenters were exposed to up to a 30 foot fall for the set of aluminum extension ladder they used to access a pump jack scaffold platform was spliced together with nylon rope.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $3880

1926.1053 B08

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $2800.00 Reduced
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the traffic away from the ladder:     a)  630 14th St., NE, Street Exposure - On or about May 8, 2018, two carpenters were exposed to a 30 foot fall form the top of an aluminum extension ladder which was located over 4 feet away (horizontal) from the scaffold platform and used by the workers to access a scaffold's platform.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $3880

1926.451 G01

Repeat Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7760.00 · Current $5600.00 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:     a)  630 14th St., NE, Street Exposure - On or about May 8, 2018, two carpenters were exposed to a 30 foot fall from the 20 inch wide platform of a pump jack scaffold and were not provided with nets, standard guardrails or personal fall arrest systems.     Nicol Construction, LLC, dba. as Nichol Construction, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1), which was contained in OSHA inspection number 1158615, citation number 1, item number 2c and was affirmed as a final order on 10-04-2016, with respect to a workplace located at 1012 St., NW, Washington, D.C. 20005.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (R) $5600
  • — Z (R) $7760

1926.451 H02 II

Repeat Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4435.00 · Current $3200.00 Reduced
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:     a)  630 14th St., NE, Street Exposure, Ground Level -  On or about May 8, 2018, a carpenter working below construction operations performed from a pump jack platform was not provided with toe boards, screens or similar safe means to protect the worker from being struck by falling tools and materials.    Nicol Construction,, LLC, dba. as Nichol Construction, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(h)(2), which was contained in OSHA inspection number 1158615, citation number 1, item number 2d and was affirmed as a final order on 10-04-2016, with respect to a workplace located at 1012 St., NW, Washington, D.C. 20005.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (R) $3200
  • — Z (R) $4435

1910.1200 G11

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(11): Safety data sheets were not made available upon request to the designated representatives or to the Assistant Secretary in accordance with the requirements of 29 CFR 1910.1020(e):  a)  630 14th. St., SE - On or about May 8, 2018, a safety data sheet for cementitious exterior house trim containing 4% silica was requested and was not provided.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

MACY'S