Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SEA SIDE SPECIALTIES INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SEA SIDE SPECIALTIES INC. in 1200 S SWINTON AVE UNIT B, DELRAY BEACH, FL 33444 (NAICS 332312). OSHA activity number 343173761.

Watch SEA Side Specialties INC. — free Get an email when a new federal OSHA severe-injury report for SEA Side Specialties INC. is published. One employer, no account, unsubscribe in one click.
Site address
1200 S SWINTON AVE UNIT B
City
DELRAY BEACH
State
FL
ZIP
33444
Mailing
305 NW 48TH AVE, DEERFIELD BEACH, FL 33442
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
6
Ownership type
A

3 citations on file for this inspection.

1910.178 P01

Serious Gravity 5 2 instances 1 exposed
Issued
Penalty
Initial $2772.00 · Current $1663.00 Reduced
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition:  a. On or about 5/22/2018, at 1200 S Swinton Ave Delray Beach, FL 33444, the Komatsu forklift (SN: 555267A) had an inoperable horn; exposing the employees to a possible struck-by hazard.  b.On or about 5/22/2018, at 1200 S Swinton Ave Delray Beach, FL 33444, the Toyota forklift (SN: 8EFG6025) had an inoperable back up alarm; exposing the employees to a possible struck-by hazard.
Recent events (2)
  • — I (S) $1663.2
  • — Z (S) $2772

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $1663.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least:  On or about 5/22/18, at 1200 S Swinton Ave Delray Beach, FL 33444, five oxygen cylinders were stored within a 8ft X 4ft storage closet along with 4 propane gas cylinders and 3 acetylene gas cylinders.
Recent events (2)
  • — I (S) $1663.2
  • — Z (S) $2772

1910.254 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3326.00 · Current $1996.00 Reduced
29 CFR 1910.254(d)(3): Special attention was not given to safety ground connections of portable welding machines:  On or about 5/22/2018, at 1200 S Swinton Ave Delray Beach, FL 33444, the insulation of the ground cable was damaged on the Miller portable welding machine.
Recent events (2)
  • — I (S) $1995.6
  • — Z (S) $3326

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343173761.