OSHA Inspection: JULIAN SPEER COMPANY INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JULIAN SPEER COMPANY INC. in ABBOTT LABORATORIES 625 CLEVELAND AVENUE, COLUMBUS, OH 43215 (NAICS 811310). OSHA activity number 343177648.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Julian Speer Company INC. — free Get an email when a new federal OSHA severe-injury report for Julian Speer Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
ABBOTT LABORATORIES 625 CLEVELAND AVENUE
City
COLUMBUS
State
OH
ZIP
43215
Mailing
5225 SINCLAIR RD, COLUMBUS, OH 43229
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
200
Ownership type
A

2 citations on file for this inspection.

1910.146 C05 II H

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 27, 2018
Abate by
Dec 3, 2018
Penalty
Initial $12,934 · Current $8,407 Reduced
29 CFR 1910.146(c)(5)(ii)(H): The employer shall verify that the space is safe for entry and that the pre-entry measures required by paragraph (c)(5)(ii) of this section have been taken, through a written certification that contains the date, the location of the space, and the signature of the person providing the certification. The certification shall be made before entry and shall be made available to each employee entering the space or to that employee's authorized representative.  a. On or about May 16, 2018 at the site located at 3300 Stelzer Road in Columbus, Ohio, the employer did not verify, through written certification, that a permit-required confined space was safe for entry when an HVAC service employee entered the space to perform maintenance on an air handler.  The employee had de-energized and locked out the electrical supply to the fan, but had not completed a written certification to declassify the permit-required confined space
Recent events (2)
  • — I (S) $8407.1
  • — Z (S) $12934

1910.147 D01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 27, 2018
Abate by
Dec 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(1): Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy.  a. On or about May 16, 2018 at the site located at 3300 Stelzer Road in Columbus, Ohio, the employer did not ensure that HVAC service employees knew of the methods/means to control the kinetic energy in the form of air flowing through ducts. An employee was injured when air flowing through a duct caused a supply fan to start spinning while it was being serviced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Julian Speer Company INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343177648.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.