NEWARK, NJ —
OSHA Inspection: MANCO PLATING INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MANCO PLATING INC. in 390 PARK AVE., NEWARK, NJ 07107 (NAICS 332813). OSHA activity number 343181830.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANCO PLATING INC.
- Site address
- 390 PARK AVE.
- City
- NEWARK
- State
- NJ
- ZIP
- 07107
- Mailing
- P.O. BOX 7025, NEWARK, NJ 07107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 15
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.133 A01
- Issued
- Sep 27, 2018
- Abate by
- Nov 16, 2018
- Penalty
- Initial $3,696 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Establishment - plating shop The employer did not require the use of eye and face protection by electroplaters who worked with solutions of hazardous chemicals including, but not limited to, hexavalent chromium, nickel, and cadmium salts, hydrochloric and nitric acids, sodium hydroxide and cyanide. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (S) $2500
- — Z (S) $3696
1910.242 B
- Issued
- Sep 27, 2018
- Abate by
- Nov 16, 2018
- Penalty
- Initial $3,696 · Current $0 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment: a) Plating shop Compressed air at 125 psig was used to blow dry racks after final water rinse. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (S) $0
- — Z (S) $3696
1910.37 B05
- Issued
- Sep 27, 2018
- Abate by
- Nov 16, 2018
- Penalty
- Initial $3,696 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) Plating area The former shop entrance next to the QC lab had no marking that it was no longer an exit. A locked metal gate on the outside of the door prevented its use. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (S) $2500
- — Z (S) $3696
1910.1200 E01
- Issued
- Sep 27, 2018
- Abate by
- Nov 16, 2018
- Penalty
- Initial $3,696 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Establishment - plating shop The employer did not fully implement a written hazard communication program when it failed to label electroplating tanks that contained hazardous chemicals including, but not limited to, hexavalent chromium, nickel, and cadmium salts, hydrochloric and nitric acids, sodium hydroxide and cyanide. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (S) $2000
- — Z (S) $3696
1910.1026 L01 II
- Issued
- Sep 27, 2018
- Abate by
- Nov 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1026(l)(1)(ii): The employer did not address at least the following hazards with employees exposed to hexavalent chromium: Cancer, eye irritation, and skin sensitization: a) Establishment - plating shop The employer's hazard communication program did not include specific information on the health hazards of hexavalent chromium.. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1027 M01 II
- Issued
- Sep 27, 2018
- Abate by
- Nov 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1027(m)(1)(ii): In classifying the hazards of cadmium at least the following hazards were not addressed: Cancer; lung effects; kidney effects; and acute toxicity effects. a) Establishment - plating shop The employer's hazard communication program did not include specific information on the health hazards of cadmium. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Sep 27, 2018
- Abate by
- Nov 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Establishment - plating shop The employer did not provide workers who voluntarily wore filtering facepiece respirators with the information in 29 CFR 1910.134 Appendix D. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1026 D01
- Issued
- Sep 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a) Establishment - plating shop The employer did not determine electroplaters' exposure to hexavalent chromium used in plating baths. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1027 D01 I
- Issued
- Sep 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1027(d)(1)(i): The employer did not determine whether any employee was exposed to cadmium at or above the action level: a) Establishment - plating shop The employer did not conduct air monitoring or compile objective data to determine whether any electroplater was exposed to cadmium. at or above the action level. Violation occurred on or about 5/24/18.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Manco Plating INC.
View Manco Plating INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343181830.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.