Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANCO PLATING INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MANCO PLATING INC. in 390 PARK AVE., NEWARK, NJ 07107 (NAICS 332813). OSHA activity number 343181830.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manco Plating INC. — free Get an email when a new federal OSHA severe-injury report for Manco Plating INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MANCO PLATING INC.
Site address
390 PARK AVE.
City
NEWARK
State
NJ
ZIP
07107
Mailing
P.O. BOX 7025, NEWARK, NJ 07107
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
15
Ownership type
A

9 citations on file for this inspection.

1910.133 A01

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 27, 2018
Abate by
Nov 16, 2018
Penalty
Initial $3,696 · Current $2,500 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    a) Establishment - plating shop    The employer did not require the use of eye and face protection by electroplaters who worked with solutions of hazardous chemicals including, but not limited to, hexavalent chromium, nickel, and cadmium salts, hydrochloric and nitric acids, sodium hydroxide and cyanide.    Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3696

1910.242 B

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Sep 27, 2018
Abate by
Nov 16, 2018
Penalty
Initial $3,696 · Current $0 Reduced
29 CFR 1910.242(b): Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment:  a)  Plating shop  Compressed air at 125 psig was used to blow dry racks after final water rinse.  Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3696

1910.37 B05

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 27, 2018
Abate by
Nov 16, 2018
Penalty
Initial $3,696 · Current $2,500 Reduced
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):    a)  Plating area    The former shop entrance next to the QC lab had no marking that it was no longer an exit.  A locked metal gate on the outside of the door prevented its use.    Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3696

1910.1200 E01

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 27, 2018
Abate by
Nov 16, 2018
Penalty
Initial $3,696 · Current $2,000 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) Establishment - plating shop    The employer did not fully implement a written hazard communication program when it failed to label electroplating tanks that contained hazardous chemicals including, but not limited to, hexavalent chromium, nickel, and cadmium salts, hydrochloric and nitric acids, sodium hydroxide and cyanide.    Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3696

1910.1026 L01 II

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 27, 2018
Abate by
Nov 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(l)(1)(ii): The employer did not address at least the following hazards with employees exposed to hexavalent chromium: Cancer, eye irritation, and skin sensitization:  a) Establishment - plating shop  The employer's hazard communication program did not include specific information on the health hazards of  hexavalent chromium..  Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1027 M01 II

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 27, 2018
Abate by
Nov 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1027(m)(1)(ii): In classifying the hazards of cadmium at least the following hazards were not addressed: Cancer; lung effects; kidney effects; and acute toxicity effects.  a) Establishment - plating shop  The employer's hazard communication program did not include specific information on the health hazards of  cadmium.  Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 9 exposed
Issued
Sep 27, 2018
Abate by
Nov 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) Establishment - plating shop  The employer did not provide workers who voluntarily wore filtering facepiece respirators with the information in 29 CFR 1910.134 Appendix D.  Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1026 D01

Other-than-serious 1 instance 9 exposed
Issued
Sep 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):   a) Establishment - plating shop  The employer did not determine electroplaters' exposure to hexavalent chromium used in plating baths.  Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1027 D01 I

Other-than-serious 1 instance 9 exposed
Issued
Sep 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1027(d)(1)(i): The employer did not determine whether any employee was exposed to cadmium at or above the action level:  a) Establishment - plating shop  The employer did not conduct air monitoring or compile objective data to determine whether any electroplater was exposed to cadmium. at or above the action level.  Violation occurred on or about 5/24/18.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Manco Plating INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343181830.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.